Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T05OT01122
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/05/2006 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 02/27/2006 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ATMOSPHERE VACUUM BREAKERS REQUIRED ON EXTERIOR HOSE BIBS. 2. WATER TIGHT ENCLOSURES REQUIRED FOR EXTERIOR OUTLETS. 3. EXPOSED KRAFT PAPER NOT ALLOWED IN STORAGE 4. DOUBLE KEYED DEADBOLT NOT ALLOWED AT EXITS 5. YOU ARE REQUIRED TO MEET ACCESSIBILITY STANDARDS (ANSI 117.1) FOR AN R-4 OCCUPANCY. THIS MEANS YOU NEED TO PROVIDE AN ACCESIBLE RESTROOM AND AT LEASTE 1 ACCESSIBLE BEDROOM. PLEASE RETURN TO PLAN REVIEW WITH DIMENSIONED FLOOR PLAN. 6. ALL COMMON ROOMS MUST BE ACCESSIBLE (THRESHOLD, DOOR SWING, ETC) 7. USE RIGID 3/4" PIPE FOR TPRU AND SLOPE DOWN. |
|
| 02/22/2006 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* NO ANSWER AT DOOR (RANG BELL & KNOCKED 1:37 PM) |