Inspection History: BUILDING - FINAL

Permit Number - T05OT01122

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/05/2006 BUILDING - FINAL Approved IVRS - Inspection :*
02/27/2006 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. ATMOSPHERE VACUUM BREAKERS REQUIRED ON EXTERIOR HOSE BIBS.
2. WATER TIGHT ENCLOSURES REQUIRED FOR EXTERIOR OUTLETS.
3. EXPOSED KRAFT PAPER NOT ALLOWED IN STORAGE
4. DOUBLE KEYED DEADBOLT NOT ALLOWED AT EXITS
5. YOU ARE REQUIRED TO MEET ACCESSIBILITY STANDARDS (ANSI 117.1) FOR AN R-4 OCCUPANCY. THIS MEANS YOU NEED TO PROVIDE AN ACCESIBLE RESTROOM AND AT LEASTE 1 ACCESSIBLE BEDROOM. PLEASE RETURN TO PLAN REVIEW WITH DIMENSIONED FLOOR PLAN.
6. ALL COMMON ROOMS MUST BE ACCESSIBLE (THRESHOLD, DOOR SWING, ETC)
7. USE RIGID 3/4" PIPE FOR TPRU AND SLOPE DOWN.
02/22/2006 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
NO ANSWER AT DOOR (RANG BELL & KNOCKED 1:37 PM)