Permit: T05OT00313

Parcel: 117140890


Addresses:

375 S STONE AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T05OT00313

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/25/2005 PLUMBING - FINAL Approved
03/23/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SHALL PROVIDE A BACKFLOW PREVENTER 007 FOR ICE MAKER. 2) SHALL HAVE ALL IN HOUSE BACKFLOW PREVENTERS TESTED & CERTIFIED BY TIME OF FINAL INSPECTION. 3) SHALL PROVIDE A P-TRAP FOR HAND SINK@ BAR INDERECT WASTE AND @ DBL COMPT. SINK. 4) SHALL PROVIDE AN EXPANSION TANK @ WATER HTR. 5) SHALL REPLACE T & P VALVE AND REMOVE FLEX LINE IN T & P DRAIN. 6) SHALL PROVIDE A 1/2" MIN INDEPENDENT DRAIN FOR 009 BACKFLOW PREVENTER FOR SODA DISPENSER
03/21/2005 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* DOOR IS LOCKED
03/16/2005 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :* 1) ALL EQUIPMENT TO BE INSTALLED AND MEET MINIMUM REQUIREMENTS FOR 94 UPC. 2) PLEASE HAVE CITY APPROVED PLAN SHOWING ALL PLUMBING EQUIPMENT.