Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T05ME00977
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/17/2006 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* ALL CORRECTIONS HAVE BEEN MADE. |
|
| 01/18/2006 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*GAS FLEX CONNECTOR CANNOT PENETRATE THE CABINET OF THE FURNACE. PROVIDE AN APPROVED GAS SHUT OFF VAVLE. PROVIDE MIN. 3 SCREWS IN ALL JOINTS OF FURNACE VENT CONNECTOR. EXTEND THE VENT PIPE MIN. 2" ABOVE EVAP COOLER EXPOSED LOW VOTTAGE WIRE OUTDOORS MUST BE IN CONDUIT. ISOLATE DISC?? LINE FROM CONTACTING SUCTION LINE. CONDENSATE CANNOT TERMIANTE INTO A PLUMBING DRAIN INSIDE A WALL. |