Permit: T05ME00876

Parcel: 136081350


Addresses:

9552 E 29TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
03/01/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
ALL CORRECTIONS HAVE BEEN MADE
02/24/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
ITEM #2 -- NEED TO TALK TO CONTRACTOR ABOUT GAS CONNECTION AT SOURCE, PRIOR TO APPROVAL
01/06/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1) PROVIDE A MINIMUM 10 POUND PRESSURE TEST ON ALL NEW GAS PIPING
2) NEED TO SEE WHERE GAS IS CONNECTED INSIDE HOUSE
3) EXTEND CONDENSATE DRAIN TO WITHIN 6" OF THE GROUND WITH AN ELBOW ON BOTTOM AND A NIPPLE TO DIVERT THE WATER AWAY FROM THE HOUSE
4) BLOCK AND CLAMP PVC ON ROOF EVERY 4'
5) NEED TO SEE CIRCUIT BREAKER
6) RECALL FOR INSPECTION