Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 11/04/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*VENT CONNECTOR ON FURNACE INSTALLED UPSIDE DOWN. CRIMPED ENDS RUNNING WRONG DIRECTION. PROVIDE A HOSE CLAMP ON CONDENSATE PUMPS |
|
| 10/28/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*PVC DRAIN PIPE ON THE COIL MUST HAVE CLEARANCE FROM THE SINGLE WALL VENT CONNECTOR. USE COPPER WITHIN 6" OF VENT. PROVIDE A HOSE CLAMP ON CONDENSATE PUMP. PROVIDE A PERMIT FOR THE ELECTIRCAL UPGRADE & A PERMIT FOR THE NEW WATER HEATER. PROVIDE A PETITION OF APPEAL FOR THE T & P 4 RELIEF DRAIN. RECALL FOR INSPECTION |