Permit: T05ME00829

Parcel: 136333520


Addresses:

2912 S HARRISON RD


Inspection Status: Denied

Inspection History: MECHANICAL - FINAL

Permit Number - T05ME00829

Inspection Description - MECHANICAL - FINAL

Inspection Status - Denied

Date Description Inspector Results Comments
05/10/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
BLOCK & CLAMP GAS PIPE AS NOTED ON PREVIOUS INSPECTION.
CONDENSATE CANNOT DRIP OVER THE EDGE OF THE ROOF.
MUST TERMINATE WITHIN 6" OF DIRT OR AN AREA THAT CAN ABSORB THE WATER. BLOCK & CLAMP PVC EVERY 4'
PAINT PVC W/LATEX PAINT. USE A ROOF JACK IF PENETRATING THE ROOF WITH DRAIN LINE.
CHECKED GAS PIPING WITH SOAPY SOLUTION.
TEST IS OK
11/16/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*PROVIDE A CONDENSATE DRAIN TO AN APPROVED LOCATION. PROVIDE A MIN 10 LB PRESSURE TEST ON ALL NEW GAS PIPING. BLOCK & CLAMP GAS PIPE NEAR SHUT OFF VALVE TO FURNACE.
LOW VOLTAGE WIRE MUST BE PROTECTED USE CONDUIT. PROVIDE A COVER ON JUNCTION BOX.
BLOCK & CLAMP ELEC. CONDUIT.