Inspection History: PLUMBING - GAS PRESSURE TEST
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/16/2006 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection :* | |
| 01/26/2006 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WATER HEATER CANNOT BE LOCATED IN CLOSET OR CONFINED SPACE OPENING INTO A BATH OR BEDROOM. EXCEPTION DIRECT VENT WATER HEATERS, IF YOU GO THIS ROUTE HAVE NEW WATER HEATER ADDED TO PERMIT. SEE 94 UPC SECTION 509.0 2) PROVIDE TEST GAUGE IN 1/10 POUND INCREMENTS FOR TESTING 3) PROVIDE BONDING OF BLDG GAS PIPING 4) THIS MAY NOT BE A COMPLETE LIST |
|
| 10/24/2005 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection : See detailed listing on site.| 999*GAS PRESSURE TEST IS BELOW THE 10 LBS MIN CHECK THE SYSTEM. |