Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
11/02/2005 MECHANICAL - FINAL Approved IVRS - Inspection :*ALL CORRECTIONS HAVE BEEN MADE. PLEASE CLOSE N.O.V
10/28/2005 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*BLOCK & CLAMP GAS LINE AT CHANGE OF DIRECTION. THE GAS SHUT OFF VALVE & THE UNION MUST BE WITHIN 3'OF THE CONNECTION TO THE UNIT.
CONDENSATE CANNOT TERMINATE INTO A SEWER VENT. MUST GO TO WITHIN 6" FO THE GROUND. PAINT EXPOSED PVC W/LATEX PAINT. IF RUNNING PVC ACCROSS THE ROOF, BLOCK & CLAMP EVERY 4' & USE A ROOF JACK IF PENETRATING THE ROOF.
60 AMP FUSES TOO LARGE. 35 AMP IS MAC FUSE SIZE. SECURE & SUPPORT THE ELEC. DISCONNECT & SEAL ANY UNUSED OPENINGS IN DISCONNECT
CENTER THE A/C UNIT ON THE STAND BETTER. UNIT IS ABOUT TO FALL OFF THE FRONT OF THE STAND. RECALL FOR INSPECTION.