Permit: T05ME00427

Parcel: 138233620


Addresses:

832 W BAFFIN DR

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
05/02/2006 MECHANICAL - FINAL Approved IVRS - Inspection :*
GAS PRESS. TEST - OK
04/17/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
SYSTEM 11 PSI
WILL NOT MAINTAIN PRESS --
04/05/2006 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
GAS PIPING MUST MAINTAIN 10 PSI MIN.
04/03/2006 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1. VERIFY THAT 1/2" CSST TUBING WILL HANDLE 120,000 BTUH NEED PRESS. TEST ON LINE FROM OLD FURNACE UP TO NEW UNIT.
2. IMPROPER FUSE SIZE. LEAVE UNIT PROPERLY FUSED.