Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/27/2005 | MECHANICAL - FINAL | Approved | ||
| 07/26/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 06/09/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : A reinspection fee has been assessed for this inspection. Multiple inspection Condensate drains still not blocked and clamped every 4' Electric wire still not secured within 12" of connections Gas line still not holding pressure Pay re-inspection fee prior to next inspection |
|
| 06/06/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* PROVIDE A MIN 10 LB TEST ON GAS PIPING. SECURE GAS PIPE IN ATTIC. WIRE SPLICES MUST BE IN A J -BOX SECURE WIRES. CONDENSATE DRAIN NOT DRAINING. PROVIDE MIN. 1/8'' PER FT SLOPE. PROVIDE THE COVER PLATE INSIDE ELEC. DISCONNECT. DO NOT USE WHITE WIRE. TAPE BOTH ENDS OF WHITE WIRE W/ BLACK TAPE. CONENSATE CANNOT TERMINATE ONTO A HARD SURFACE. SEAL OPENING IN OUTSIDE WALL. |