Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/10/2005 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
| 05/19/2005 | MECHANICAL - FINAL | Partial Approval | IVRS - Inspection :* 1) FRONT GROUND LEVEL UNIT: GAS PRESSURE TEST 8 PSI 2) NOT MAINTAINING PRESSURE 3) PVC CONDENSATE PIPING, NEEDS TO BE PAINTED, BOTH UNITS 4) NEW WATER HEATER ENCLOSURE SHOULD BE CORRECTED. ? VENT PIPES TERMINATION WITHIN 2 FT. CENTER OF 2 WINDOWS BELOW TOPS. NEED TO RUN 2 FT. ABOVE WINDOWS. FLEX GAS LINE RUNNING THRU WALL OF ENCLOSURE |
|
| 04/29/2005 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* UNIT 1 GAS LINE NOT HOLDING PRESSURE. A.C UNIT NEEDS TO BE MIN. 12" FROM WALL FOR ADEQUATE AIR FLOW TO CONDENSOR COIL OR PROVIDE INSTALL INSTRUCTOR PROVING 4" IS ADEQUATE. UNIT #2 GAS LINE & ELECT. CONDUITS ARE BLOCKING ACCESS TO SERVICE PANEL. |