Case: T05FR01905

Parcel: 12108001B

Inspection Status: Approved

Inspection History: INSP - LIFE SAFETY

Case Number - T05FR01905

Inspection Description - INSP - LIFE SAFETY

Inspection Status - Approved

Date Description Inspector Results Comments
02/13/2006 INSP - LIFE SAFETY Approved Both abated 2/13/06.
01/12/2006 INSP - LIFE SAFETY Violation TFC 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated.
Order: 1. Cover fan in bathroom with approved cover. 2. Power strips are not to be used in tandem.
01/12/2006 INSP - LIFE SAFETY Violation TFC 605.3 Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment.
Order: clear area around electrical box on back wall.