Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Violation
Inspection History: VIOL - MEANS OF EGRESS
Case Number - T05FR00920
Inspection Description - VIOL - MEANS OF EGRESS
Inspection Status - Violation
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/20/2005 | VIOL - MEANS OF EGRESS | Violation | TFC 1008.1.8.3- A readil visible durable sign shall be posted above the door stating "THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED". The letters shall be 1" on a contrasting background. | |
06/20/2005 | VIOL - MEANS OF EGRESS | Violation | TFC 1008.1.8- Doors shall be readily openable from the eggress side without the use of a key, special knowledge or effort. Remove hasp and latch. | |
06/20/2005 | VIOL - MEANS OF EGRESS | Violation | TFC 1009.11- Stairways shall have handrails. Rails shall not be less than 34" and not greater than 38" from the tread and shall be continuous to the nose of the last riser. | |
06/20/2005 | VIOL - MEANS OF EGRESS | Violation | TFC 1012.1- Guards shall be located along open-sided walking surfaces which are located more than 30" above grade. Guards shall be of adequate strength. | |
06/20/2005 | VIOL - MEANS OF EGRESS | Violation | TFC 1012.2- Guards shall form a protective barrier not less than 42" high. |