Case: T05FR00717

Parcel: 124182510


Addresses:

1249 E 21ST ST

Inspection Status: Approved

Inspection History: VIOL - BUILDING SVCS & SYSTEMS

Date Description Inspector Results Comments
06/15/2005 VIOL - BUILDING SVCS & SYSTEMS Approved
05/18/2005 VIOL - BUILDING SVCS & SYSTEMS Violation 605.1 - Identified electrical hazards shall be abated. 1) romex from bathroom light to heater removed 2) open wiring splices outside ABS room 3) GFI needed above outside sink

605.3 - A clear working space of 30''Wx36''Dx78''H shall be maintained in front of electrical service equipment - outside NE corner

605.5 - extension cords shall not be used as a substitute for permanent wiring - trailer, ABS area

605.6 - open junction boxes shall be prohibited - blanks needed in breaker panel outside NE corner.