Inspection History Details
Inspection Status: Correction Required
Inspection History: VIOL - BUILDING SVCS & SYSTEMS
Case Number - T05FR00464
Inspection Description - VIOL - BUILDING SVCS & SYSTEMS
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.5 Extinsion cords shall not be a substitute for permanent wiring. Extension cords shall be removed. | |
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.6 Open junction boxes shall have approved covers. | |
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.1 Junction box at coffee machine area celing shall be secured. | |
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.1 Electrical panel in kitchen area shall have blanks inserted in areas where breakers are missing. | |
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605.3 Working space shall be maintained in front of electrical panel. | |
| 04/06/2005 | VIOL - BUILDING SVCS & SYSTEMS | Correction Required | 605 The light fixtures in the stockroom shall be repaired so wiring is not exposed. |