Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2006 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :*INSTALL W.P BOXES FOR EXTERIOR CONDUCTORS MAKE SURE 3 WIRE OUTLETS ARE GROUNDED-OTHERWISE USE 2 WIRE OUTLETS OR GFI DISHWASHER AND DISPOSAL NEED TO BE WIRED PROPERLY MAIN GROUNDING ELECTRODE ( CONDUCTOR) TO GROUND RODS APPEARS TO BE CUT IDENTIFY CKTS IN PANEL AND CLOSE OFF OPENINGS BETWEEN BREAKERS HAVE AN ELECTRICIAN CHECK HOUSE FOR OTHER PROBLEMS |
|
| 01/11/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245*PROVIDE ACCESS TO INSIDE OF HOUSE FOR MY INSPECTION |
|
| 01/04/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1) PLEASE PROVIDE ACCESS TO INTERIOR OF BLDG FOR INSPECTION |