Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T05EL02443

Parcel: 11941248D


Addresses:

1711 W AJO WY


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T05EL02443

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
01/18/2007 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
01/11/2007 ELECTRIC - RECONNECT Denied IVRS - Inspection :
A reinspection fee has been assessed for this inspection. Multiple inspectio
A REINSPECTION FEE IS ASSESSED NO COMPLIANCE WITH NOTES FROM PREVIOUS INSP.

1. PERMIT REQUIRED FOR SERVICE UPGRADE, GROUND PER CODE.
2. MC INSTALLATION BELOW SERVICE PANEL NOT PER CODE, CABLE SHEATH BROKEN IN SEVERAL PLACES, BENDING RADIUS TO SHORT.
3. SERVICE TIED INTO TEP PRIOR TO APPROVAL.
4. CONDUIT & J-BOX UNDER CARPORT NOT SUPPORTED.
5. SERVICE PANEL MUST HAVE CIRCUIT BREAKERS PER SAME MANUF. AS PANEL.
6. OUTSIDE RECEPTS IN BACK NEED TO BE GFI & SUPPORTED
INSTALL PROPER BUBBLE COVERS.
7. WATER HEATER NOT INSTALLED COMPLETELY
8. NEW RECEPTS OVER SINK MUST BE GFI
9. BASEBOARD HEATERS NOT WIRED PER CODE
10. NEW GROUND TYPE RECEPTS ON UNDERGROUND SYSTEM

PAY REFEE AT 201 N STONE
12/13/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
NOTES:
1. THIS DWELLING IS IN NEED OF NUMEROUS ELECTRICAL REPAIRS. OBTAIN THE SERVICES OF A C-11 LICENSED ELECTRICAL CONTRACTOR TO MAKE SERVICE REPAIRS AND WIRING THROUGHOUT DWELLING FOR CODE COMPLIANCE/REPAIRS.
2. SMOKE DETECTORS REQUIRED IN SLEEPING AREAS - UNIT NOT OCCUPIED
3. HEATING & COOLING EQUIP. TO BE IN WORKING CONDITION PLEASE HAVE ELECTRICAL CONTRACTOR CONTACT DAN SANTACRUZ OR RAY MAJUTA AT 791-5550 EXT 1136