Permit: T05EL02366

Parcel: 129051700


Addresses:

2027 E 18TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
12/08/2005 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
12/05/2005 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
The service is not per code.| 210* FIX MULTI WIRE CKT'S ON TWIN BREAKERS ( PUT HOTS ON DIFFERENT PHASES)
LABEL PANEL DIRECTORY
FINISH INTERIOR ELECTRICAL
DRIVE GROUND RODS FLUSH
12/02/2005 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
See detailed listing on site.| 999*PER TEP & IRC A METAL RAISED ADDRESS LABEL IS REQUIRED AT THE ELECTRICAL SERVICE
FINISH ELECTRICAL IN KITCHEN
11/29/2005 ELECTRIC - SERVICE UPGRADE Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*1) CHASE NIPPLES NOT ALLLOWED UNLESS LOCKNUTS INSTALLED-OR CLOSE NIPPLES.
2) PERMIT REQUIRED FOR ADDITIONAL CIRCUITS.
3) CHANGE DESCRIPTION TO 100 AMPS.