Permit: T05EL02205

Parcel: 123110940


Addresses:

1436 E LESTER ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T05EL02205

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/07/2011 ELECTRIC - FINAL Approved
11/03/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO ONE ON SITE, MAKE SURE SOMEONE WILL BE AVAILABLE WHEN MAKING INSPECTION REQUEST
10/06/2011 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
11/03/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
The service is not per code.| 210*CONENCT RANGE NEUTRAL TO INSULATED ( WHITE) CONDUCTOR, AND NOT TO EQUIPMENT GROUND AT BACK DOOR J-BOX ( EXTERIOR)
CAP UNUSED NEUTRAL AND VERIFY CORRECT POLARITY TO EXISISTING BRANCH CKT'S @ BACK DOOR J-BOX ( INSIDE)
REMOVE MAIN GROUNDING ELECTRODE CONDUCTOR FROM BRANCH CKT J-BOX AND RUN DIRECTLY TO SERVICE DISCONNECT ENCLOSER
( J-BOX ALREADY GROUNDED THROUGH NIPPLE AND IS NOT PART OF GROUNDING ELECTRODE SYSTEMS.
11/01/2005 ELECTRIC - FINAL Not ready for Inspection