Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/02/2006 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/16/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*INSTALL ANTI OXIDATION PASTE ON ALL ALUM. TERMINATIONS INCLUDING NEUTRAL & GROUNDING CONDUCTORS |
|
| 11/09/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ANTI-OXIDATION POSTE TO ALUM TERMINATIONS (DRYER AND RANGE CIRCUITS) 2) INSTALL LOCK NUT BETWEEN LB AND PANEL TO ASSURE CONDUIT BONDING AT PANEL-LB CONNECTION (LOCK NUT TO CUT THRU ENAMEL PAINTED SURFACE 3) SECURE 3/4" EMT WITHIN 3' OF ELECTRIC PANEL 4) DBL LUGGED BREAKERS IS NOT ACCEPTABLE |