Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05EL02173

Parcel: 112041060


Addresses:

2617 E LA MADERA DR

Inspection Status: Approved

Inspection History: ELECTRIC - SERVICE UPGRADE

Date Description Inspector Results Comments
02/17/2006 ELECTRIC - SERVICE UPGRADE Approved IVRS - Inspection :*
02/03/2006 ELECTRIC - SERVICE UPGRADE Not ready for Inspection IVRS - Inspection :*
1. PLEASE VERIFY 2ND GROUND ROD
2. WHERE IS GAS BOND
3. LABEL BREAKERS
4. CORRECLTY IDENTIFY UNGROUNDED CONDUCTOR
5. BOND SERVICE ENCLOSURE
6. SEPARATE GROUNDING EQUIPMENT CONDUCTORS