Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 11/25/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*NOTES INSTALL BOND BUSHING AT 1" CONDUIT TERM. INTO SERVICE & SUPPORT CONDUIT. BOND NEUTRAL IN SERVICE PANEL. CONDUCTORS FROM METER BASE TO PANEL TO SMALL SHOULD BE # 2 |
|
| 10/19/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* COOLER NOT WIRED PER CODE, INSTALL W/P BOX, RECEPT, COVER. INSTALL SMOKE DETECTORS IN SLEEPING AREAS. OUTSIDE RECEPT. BY WATER HTR NEED TO BE GFI PROTECTED WITH W/P COVER PANEL BELOW METER WAS REPLACED RECENTLY. NOT INSTALLED PROPERLY, CANNOT OPEN COVER DUW TO WRONG TYPE SCREWS FOR HUB AT T & P. ALSO NOT GROUNDED PROPERLY, INSTALL GROUNDING ELECTRODE SYSTEM, BOND WATER & GAS PIPING. REMOVE 240 V OUTLET BELOW PANEL OR INSTALL PER CODE. |