Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - UNDERGROUND
Permit Number - T05EL02106
Inspection Description - ELECTRIC - UNDERGROUND
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/06/2006 | ELECTRIC - UNDERGROUND | Approved | IVRS - Inspection :* | |
10/20/2005 | ELECTRIC - UNDERGROUND | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
10/19/2005 | ELECTRIC - UNDERGROUND | Denied | UPGRADES NOW REQUIRE TWO GROUND RODS 6'APART IN ADDITION TO WATER & GAS BONDS SCRAPE PAINT OF LOCATION WHERE GAS BOND CONNECTED PERMIT FOR NEW WIRING IN PANEL MUST BE OBTAINED AND INSPECTED-NEW WIRING GOING DOWN 1" EMT INTO BASEMENT, DRYER CIRCUIT, CIRCUIT 19-20 MARKED SPARES BUT HAVE NEW WIRING PANEL REQUIRES SIEMANS BREAKER AS PER INSIDE LABEL. |