Permit: T05EL01344

Parcel: 124122400


Addresses:

1422 E 13TH ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
05/10/2007 ELECTRIC - FINAL Approved IVRS - Inspection :*
05/08/2007 ELECTRIC - FINAL Cancelled IVRS - RI canceled
01/09/2007 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. INSTALL 240V DRYER OUTLET IN W/P BOX & COVER BELOW SERVICE PANEL.
2. 110V GFI RECEPT REQUIRES BUBBLE TYPE COVER.
3. EXPOSE GROUND RODS, BOND WATER & GAS PIPING.
4. PROVIDE APPROVED PLANS/PERMIT FOR NEW INSIDE WIRING.
5. THE TOP SHIELDED AREA OF PANEL IS DEDICATED FOR UNPROTECTED BUS -- DO NOT RUN LOAD CONDUCTORS THRU OR IN THIS AREA.