Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2005 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* 1) OK TO CLEAR RECONNECT #1 |
|
| 08/03/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) TWO SERVICES AT THIS ADDRESS #1 AND #2. SERVICE #1 MUST BE ON THIS PERMIT. WHAT DOES #1 FEED ? NEED TO INSPECT LOAD CONNECTION WIRING. RE-CALL INSPECTION WHEN SOMEONE IS HOME. RANG DOOR BELL-NO ANSWER |
|
| 06/27/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ADDRESS SERVICE PERMANENTLY. 2. REMOVE UNAPPROVED WIRING AT BOTTOM OF SERVICE DISCONNECT. 3. OWNER TO CORRECT WIRING AT SERVICE DISCONNECT WHICH HAS IMPROPER EXPOSED WIRING TO RECEPTACLE AND EXTENSION CORD ON FENCE AND GROUNS. 4. FEEDER TO MH CANNOT BE RUN IN WHITE PLASTIC CONDUIT. 5. ADDITION SERVICE TO SHED IN STEEL CONDUIT? 6. SMOKE DETECTORS IN BEDROOMS. 7. WIRING UNDER PANEL IN BEDROOM TO BE CORRECTED. |
|
| 06/23/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : There is no access to the site.| 920* UNIT MUST HAVE ACCESS, BLD MUST BE OPEN RECALL INSPECTION. |