Permit: T05EL01182

Parcel: 112074740

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/25/2008 ELECTRIC - FINAL Approved
02/04/2008 ELECTRIC - FINAL Not ready for Inspection CONTRACTOR TO MAKE CORRECTIONS BEFORE RECALLING THIS INSPECTION. NEW CONTRACTOR HAS TAKEN OVER JOB AFTER PREVIOUS OWNER ALLOWED THIS PERMIT TO EXPIRE.
05/24/2006 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*
1. FINISH PREVIOUS NOTES ITEMS
2. MAIN BREAKER TO HAVE MANUFACTURERS HOLD DOWN.
05/18/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245*
IT LOOKS LIKE SOME CORRECTIONS HAVE NOT BEEN MADE.
CALL RICK H. TO SCHEDULE THIS INSPECTION WITH HIM.
HIS NUMBER IS 909-4749
05/17/2006 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
CALLED AHEAD AS REQUESTED NO ANSWER -- PLEASE RECALL AND LEAVE MESSAGE.
11/30/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :*PLEASE VERIFY GAS & WATER BONDING
NO ENTRANCE THRU METER SECTIONOF ALL IN ONE
SEAL ENTRANCES ABOVE CURRENT CARRYING PARTS
TIGHTEN LOOSE FITTINGS
RISER HARDWARE TO BE 1/4" MINIMUM
RECEPTACLE COVERS TO BE WEATHERPROOF WETHER OR NOT PLUGGED INTO 406.8
CORRECTLY IDENTIFY UNGROUNDED CONDUCTORS
# 8 NM CABLE TO HAVE BREAKER AMPACITY SIZED PER 334.80
A MAIN BREAKER IS EEDED PER 25.31 & 225.32 ALSO A GROUNDING ELECTRODE SYSTEM
TIGHTEN LOOSE CONNECTORS TO JUNCTION BOX. ALL CABLES TO BE SECURED TO BOX. SUPPORT CABLES WITHIN 12" OF BOX GROUND JUNCTION BOX.
CHASE NIPPLE NOT AN APPROVED FITTING WITH CONDU???
VERIFY DERATING OF CIRCUITS PER 310.15