Inspection Status: Partial Approval
Inspection History: ELECTRIC - FINAL
Permit Number - T05EL01122
Inspection Description - ELECTRIC - FINAL
Inspection Status - Partial Approval
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/28/2005 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* | |
06/20/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ONLY (1) ONE CONDUCTOR PER TERMINAL LUG. 2) SEAL ENTRANCES ABOVE CURRENT CARRING PARTS. 3) TIGHTEN LOOSE FITTINGS. 4) SUPPORT SEAL TILE AND CONDUITS AS PER CODES. 5) PLEASE EXPOSE NEW UNDER GROUND PVC FOR INSPECTION. 6) COVERS TO BE WEATHERPROOF WEATHER OR NOT PLUGGED IN 408.6. 7) PLEASE VERIFY GAS & WATER BONDING 8) A MAIN DISCONNECTION MEANS IS NEEDED AT SECONDARY B???. 9) DISCONNECTING MEANS NOT TO BE ABOVE 6" 7" |