Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/10/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The smoke detectors have not been installed per code.| 165* 1) EACH BEDROOM MUST BE FILLED WITH A SMOKE DETECTOR AND EACH HALLWAY AT A POINT NEAR THE BEDROOM. YOU NEED A TOTAL OF FOUR SMOKE DETECTORS-1 IN EACH BEDROOM, FRONT HALLWAY AND CEILING IN FAMILY ROOM NEAR BEDROOM DOOR 2) MOUNTING INSTRUCTIONS: LOCATE AWAY FROM AIR SUPPLY REGISTERS-NOT CLOSER THAN 3 FEET 3) WALL-NOT CLOSER THAN 6" TO CEILING NOR LOWER THAN 12" FROM CEILING 4) CEILING-NOT CLOSER THAN 16" TO WALL AND NOT CLOSER THAN 18" TO CORNERS 5) COMPLETE AND RECALL INSPECTION |