Permit: T05EL01045

Parcel: 123091530


Addresses:

3039 E DRACHMAN ST

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/30/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/10/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
The smoke detectors have not been installed per code.| 165*
1) EACH BEDROOM MUST BE FILLED WITH A SMOKE DETECTOR AND EACH HALLWAY AT A POINT NEAR THE BEDROOM. YOU NEED A TOTAL OF FOUR SMOKE DETECTORS-1 IN EACH BEDROOM, FRONT HALLWAY AND CEILING IN FAMILY ROOM NEAR BEDROOM DOOR
2) MOUNTING INSTRUCTIONS: LOCATE AWAY FROM AIR SUPPLY REGISTERS-NOT CLOSER THAN 3 FEET
3) WALL-NOT CLOSER THAN 6" TO CEILING NOR LOWER THAN 12" FROM CEILING
4) CEILING-NOT CLOSER THAN 16" TO WALL AND NOT CLOSER THAN 18" TO CORNERS
5) COMPLETE AND RECALL INSPECTION