Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
Permit Number - T05EL01000
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* NEED PERMIT FOR SPACE #11 |
|
| 06/01/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* FOR #22 OK FINAL #22 |
|
| 05/31/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* 1) RE-DO CABLES GOING INTO PANEL 2) ROMEX TO BE FULLY INTO CONN. |
|
| 05/04/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 05/01/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR UNIT #22 1. REPLACE POWER CORD THIS ONE DAMAGED 2. CAN'T LOCATE SUBPANEL? |
|
| 04/30/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* INSPECTION FOR UNIT #6 1. IN SUB-PANEL SEAL UNUSED OPENINGS, 2 CONDUCTORS UNDER SAME GROUND LUG NOT ALLOWED - TERMINATE BOTH THESE GROUNDS TO GROUND BAR. USE PROPER CONNECTORS FOR ROMEX ENTERING PANEL. INSPECTION FOR UNIT #5 - INSTALL PANEL COVER, ONLY SAME SIZE GROUNDS UNDER SAME GROUND BAR TERMINATION. REMOVE LIGHT OVER KITCHEN SINK (SPLICE IN CORD) |
|
| 04/26/2007 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :$ WHAT UNIT? LEAVE MESSAGE |
|
| 04/18/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 04/16/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* INSPECTION FOR UNIT #12 1. TERMINATE ALL GROUND IN SUB-PANEL TO A GROUND BAR NOT A SPLIT BOLT 2. J-BOX COVER TO FURNACE MISSING 3. INSTALL ALL LIGHT BULBS AND GLOBES ON FIXTURES 4. HAVE OPEN WIRING KITCHEN EX. FAN 5. HAVE OPEN SPLICES IN COOLER ON ROOF. |
|
| 04/11/2007 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection :* | |
| 04/10/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 04/06/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) UNIT #12: REPAIR OUTSIDE LIGHT FIXTURE (HANGING DOWN) 2) ISOLATE GROUNDS AND NEUTRALS IN SUB PANEL 3) 60 AMP MAIN BREAKER AT PEDESTAL (POST) FED WITH #10 WIRE 4) SMOKE DETECTORS TO BE IN WORKING CONDITION 5) QUALIFIED ELECTRICIAN OR LICENSED CONTRACTOR TO DOE WORK 6) EXPOSED ROMEX/CABELING AT SUB PANEL 7) CHECK OUT ELECTRICAL SYSTEM FOR PROBLEMS-OLD UNIT |
|
| 02/12/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 02/08/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL SPACE NUMBER AT DISCONNECT 2) POWER CORD NOT PROPERLY SECURED TO TRAILER PANEL 3) TRAILER PANEL HAS LOOSE CONNECTIONS, IMPROPERLY TERMINATED GROUNDS, TO HIGH BREAKER-15 AMP MAX ON 14 GA WIRE 4) HAVE SEVERAL LOOSE DEVICES, BROKEN PLATES AND MISSING PLATE SCREWS 5) SMOKE DETECTORS TO CLOSE TO CEILING-CHECK INSTALLATION INSTRUCTIONS |
|
| 02/05/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WAS HERE AT 10:35 AM-NO ONE HOME 2) LOCKED, ALSO CALLED PHONE NOT WORKING |
|
| 01/09/2007 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 01/08/2007 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* DENIED FOR #8 YOUR RECEPTACLE BELOW BREAKER BOX NEEDS TO BE SUPPORTED. |
|
| 12/22/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. NOT ENOUGH ROOM IN BREAKER BOX AT UNIT FOR SPACE, COVER WILL NOT CLOSE PROPERLY. ALSO, COVER CODE WIRING, CONDUIT END MUST HAVE INSULATING BUSHING. SEE NOTE LAST INSP. |
|
| 12/11/2006 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. TRAILER DISCONNECT IS OVERFUSED AT SERVICE - SHOULD BE MAX 50 AMP. 2. DISCONNECT FOR TRAILER HAS OPEN SPLICES ON PHASE CONDUCTORS. 3. DISCONNECT COVER WILL NOT STAY ON. 4. PROVIDE ACCESS TO INTERIOR OF TRAILER FOR INSPECTION NEED NO OPEN WIRING AND PROPERLY INSTALLED, WORKING SMOKE DETECTOR IN EACH BEDROOM AND HALLWAY. |
|
| 06/08/2006 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* | |
| 08/31/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CALLED AT 11:05 AM TO NOTIFY OF INSPECTION. NO ONE ON SITE DURING INSPECTION 2) LEAVE THE CHORD CAMPER OUT-INSPECTION IS TO VERIFY TYPE OF CHORD AND CAP TO BE USED TO PLUG INTO RECEPTACLE-COVER AT SERVICE TO COVER PLUG: INSERTED |
|
| 08/26/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG TYPE OF BOX USED FOR 30 AMP RECEPTACLE 2) WRONG TYPE OF COVER ON BOX USED,. MUST COVER PLUG AT ALL TIMES 3) UF WIRING WRONG TYPE ON CORD CAP, ALSO IT'S SPLICED UNDER TO SO CORD UNDER TRAILER 4) SO ENTERING SUB PANEL INSIDE DOES NOT REACH CONNECTOR |
|
| 08/25/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SAME REASON AS OF INSPECTION 8.16.05 ON ONE ON SITE - WHICH UNITS ARE REQUESTED LEFT MESSAGE ON # PHONE LISTED ABOVE (RAY) |
|
| 08/16/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CALLED PHONE NUMBER LISTED-NO ANSWER-WHICH UNITS DO YOU WANT INSPECTED-I NEED TO MEET SOMEONE ON THIS PROJECT |
|
| 07/25/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 07/12/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 18,8,12 NEED INSPECTION. #8 MAIN DISCONNECT NEEDS TO BE REPLACED -ALSO CORD. 2 CORD DOES NOT REACH INTO PANEL, 2. CIRCUITS TIED TOGETHER 3. CORD DROM DISCONNECT TO TRAILER NO GROUND. 4. REPLACE WITH LISTED CORD& DISCONNECT. # 12 NO LOT NUMBER NO PULL OUT HANDLE AT FUSE NUMBER DISCONNECT AT SPACE. # 18 NUMBER DISCONNECT-SEAL HOLES AT BOTTOM NUMBER LOT. |
|
| 05/19/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : The service entrance is not per code.| 215* 1) THE LOT NUMBERS MUST BE FACTORY PAINTED PRODUCTS SIMILAR TO THE TYPE USED ON TRAILERS (23-24 ETC.) EACH TRAILER RECEPTACLE BOX MUST HAVE A NUMBER ANE EACH LOT MUST HAVE A DURABLE STAKE AND NUMBER AT THE FRONT OF THE LOT. THE STAKE MAY BE REMOVED WHEN A TRAILER IS INSTALLED AND ADDRESSED. SPRAY PAINT ON CARD BOARD IS NOT ACCEPTABLE 2) AT SPACE 8-INSTALL A STAKE OR POST TO WHICH THE BOX CAN BE SCREWED INTO. BACK OF BOX TO POST. THE 2 X 4 YOU INSTALLED DOES NOT PROVIDE THE REQUIRED BACK BOARD SUPPORT 3) CORRECT AND RECALL INSPECTION |
|
| 05/18/2005 | ELECTRIC - RECONNECT | Partial Approval | IVRS - Inspection :* OK TO CLEAR HIGHLIGHTED UNITS ONLY. RETURN TO DEVELOPEMENT SERVICES AND HAVE ADDRESS CORRECTED. #8 REMOUNT ELECTRICAL BOX-EXTERIOR. #1 GOOD TO GO OK TO CLEAR. #4 GOOD TO GO. OK TO CLEAR. #5 NOT DEFINED. #6 NOT DEFINED. #12 NEED SPACE #'S MUST BE VISIBLE FROM STREET. #13 NEED SPACE #'S MUST BE VISIBLE FROM STREET. #18 NEED SPACE #'S MUST BE VISIBLE FROM STREET. #20 NEED SPACE #'S MUST BE VISIBLE FROM STREET. |