Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T05EL00976

Parcel: 133251270


Addresses:

8460 E ROSEWOOD ST

Inspection Status: Partial Approval

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/02/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :* 1) WE STILL NEED VERIFICATION OF AC PERMIT. ELECTRICAL CONTRACTOR DONE.
05/26/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) A SEALING DEVICE IS NEEDED FOR ENTRANCES ABOVE CURRENT CARRING PARTS
2) TIGHTEN LOOSE FITTINGS
3) FINISH DRIVING GROUND RODS
4) PLEASE VERIFY NEW A/C PERMIT #5 PREVIOUS INSPECTION
05/24/2005 ELECTRIC - FINAL Partial Approval IVRS - Inspection :*
1) FINISH WATER BOND AT WATER HEATER
2) FINISH 2ND GROUND ROD
3) STRAP GROUND TO BLDG
4) FINISH CROSS OVER CONNECTIONS
5) PLEASE VERIFY NEW A/C PERMIT
6) OK TO CLEAR SERVICE INCREASE
7) CALL TEP 11:55 AM