Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/14/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/06/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* NOTES: 1) OUTSIDE POLE LT NOT WIRED PROPERLY, SPLICES NEED TO BE IN APPROVED J-BOX. 2) RE ATTACH OUTSIDE LIGHT FIXTURE & BOX TO WALL-WEST OUTSIDE. 3) REPAIRED RECEPTACLE UNDER SERVICE PANEL NEEDS TO BE GFI TYPE |
|
| 05/23/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CIRCUIT BREAKER IN MAIN SERVICE DBL LUGGED 2) KITCHEN PANEL IN CABINET AREA, ALSO HAS SEVERAL CIRCUIT BREAKERS MULTI LUGGED 3) NEUTRAL BAR IN KITCHEN SUB-PANEL MULTI LUGGED 4) ADDRESS METER AS 4750 |
|
| 04/14/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOTES: 1) REPAIR OUTSIDE LIGHT NORTHWEST CORNER OF HOUSE BELOW ROOF. 2) REPAIR RECEPT. COVER UNDER SERVICE, ALSO I.D SERVICE FOR 4750 ( 2 SERVICES) BOTH SERVICES IN NEED OF REPAIR, SUPPORT MIDWEST BOX TO WALL. 3) SERVICE ON RIGHT SIDE NEEDS TO BE IDENTIFIED, DISCONNECT BOX IN NEEDS TO BE REPLACES, CONDUCTORS ARE OVERHEATING, ALSO RAIN DAMAGE, RE-SUPPORT RISER CONDUIT TO WALL. 4) INSTALL SMOKE DETECTORS IN BEDROOMS. 5) EXPOSED ROMEX FOR OUTSIDE POLE LIGHT, SHOULD BE IN CONDUIT. |