Permit: T05EL00691

Parcel: 135030900


Addresses:

6573 E CALLE DENED


Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T05EL00691

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2005 ELECTRIC - RECONNECT Approved IVRS - Inspection :*APPROVED OK TO CLEAR
04/08/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :1) ROMEX EXTENSION CORD IS NOT LEGAL AS WIRED PLEASE REPLACE PER NEC OR REMOVE ALTOGETHER 2) PROPERLY WIRE TRANSFORMER AT LAUNDRY ROOM. 3) INTALL BLANK PLATE OVER EXPOSED WIRES @ LAUNDRY ROOM J-BOX ( SWITCH LOCATION) OR INSTALL SWITCH & PLATE. 4) INSTALL MISSING DEVICE PLATES THROUGH OUT. 5) GROUNDING RECEPTACLES NOT ALLOWED ON UNGROUNDED CIRCUITS UNLESS GFCI PROTECTED 6) REPLACE DAMAGED RECEPTACLES. 7) INSTALL SMOKE DETECTORS IN HALLWAY. 8) LIGHT BOX @ S.WEST BEDROOM NEEDS A LIGHT FIXTURE OR BLANK PLATE.