Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 04/12/2005 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection :*APPROVED OK TO CLEAR |
| 04/08/2005 |
ELECTRIC - RECONNECT |
|
Denied |
IVRS - Inspection :1) ROMEX EXTENSION CORD IS NOT LEGAL AS WIRED PLEASE REPLACE PER NEC OR REMOVE ALTOGETHER 2) PROPERLY WIRE TRANSFORMER AT LAUNDRY ROOM. 3) INTALL BLANK PLATE OVER EXPOSED WIRES @ LAUNDRY ROOM J-BOX ( SWITCH LOCATION) OR INSTALL SWITCH & PLATE. 4) INSTALL MISSING DEVICE PLATES THROUGH OUT. 5) GROUNDING RECEPTACLES NOT ALLOWED ON UNGROUNDED CIRCUITS UNLESS GFCI PROTECTED 6) REPLACE DAMAGED RECEPTACLES. 7) INSTALL SMOKE DETECTORS IN HALLWAY. 8) LIGHT BOX @ S.WEST BEDROOM NEEDS A LIGHT FIXTURE OR BLANK PLATE. |