Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/12/2005 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
| 03/07/2005 | ELECTRIC - RECONNECT | Cancelled | CANCELLED PER CLARENCE LOCH PHONE #623-0051 | |
| 03/07/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* NO ONE HOME PLEASE RECALL |
|
| 03/04/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SERVICE DISCONNECT HAS MULTIPLE LUGGING ON LINE AND LOAD SIDE TO BE REMOVED AND CORRECTED. 2) 30AMP DISCONNECT NEXT TO SECURE ALSO HAS DOUBLE LUGGING ON LOAD SIDE. 3) SUB PANEL IN PANTRY ALL FUSING CURRENTLY 30AMPS SHOULD BE 20-20AMP CIRCUITS, 15 FOR 14 AMP CIRCUIT. 4) WASHER CIRCUIT-ADDED TO 230 V DRYER CIRCUIT ALSO THESE CIRCUITS HAVE TO BE PHYSICALLY PROTECTED. 5) SUB PANEL IN PANTRY NEEDS TO BE CLEANSED UP SUCH AS TERMINATIONS AND DUST. ??AN ELECTRICIAN BE BROUGHT IN TO CORRECT WIRING THEN OUT HOUSE & VERIFY ALL ELECTRICAL RECALL FOR INSPECTION. |