Permit: T05EL00428

Parcel: 11502123B


Addresses:

316 E LESTER ST

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
04/12/2005 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
03/07/2005 ELECTRIC - RECONNECT Cancelled CANCELLED PER CLARENCE LOCH PHONE #623-0051
03/07/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999* NO ONE HOME PLEASE RECALL
03/04/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) SERVICE DISCONNECT HAS MULTIPLE LUGGING ON LINE AND LOAD SIDE TO BE REMOVED AND CORRECTED. 2) 30AMP DISCONNECT NEXT TO SECURE ALSO HAS DOUBLE LUGGING ON LOAD SIDE. 3) SUB PANEL IN PANTRY ALL FUSING CURRENTLY 30AMPS SHOULD BE 20-20AMP CIRCUITS, 15 FOR 14 AMP CIRCUIT. 4) WASHER CIRCUIT-ADDED TO 230 V DRYER CIRCUIT ALSO THESE CIRCUITS HAVE TO BE PHYSICALLY PROTECTED. 5) SUB PANEL IN PANTRY NEEDS TO BE CLEANSED UP SUCH AS TERMINATIONS AND DUST. ??AN ELECTRICIAN BE BROUGHT IN TO CORRECT WIRING THEN OUT HOUSE & VERIFY ALL ELECTRICAL RECALL FOR INSPECTION.