Permit: T05EL00309

Parcel: 130121460


Addresses:

3738 E SHEPHERD PL

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
02/25/2005 ELECTRIC - RECONNECT Approved IVRS - Inspection :*
02/23/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
02/14/2005 ELECTRIC - RECONNECT Denied IVRS - Inspection :
The wiring is not complete or does not comply with code.| 245* NOTES: 1) ROOF TOP RECEPTS MUST BE IN W/P BOXES WITH W/P COVERS, GFCI PRTECTED. 2) WASHER OUTLET MUST BE IN WEATHER PROOF BOX & COVER, GFCI PROTECTED, DRYER OULET. ALSO IN W/P BOX & COVER, ALSO SWITCH BY OUTLETS. 3) INSTALL MISSING COVERS FOR AC UNIT/FURNACE. 4) FUSE PANEL BEHIND KITCHEN CABINET NOT ACCESSIBLE- CHECK FOR OVERSIZE FUSES. 5) NO ENTRY LIGHT OUSIDE FRONT DOOR. WORK MUST BE DONE BY C-11 LICENSED CONTR. REC-CALL INSP. WHEN DONE.