Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T05EL00240
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/07/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
02/04/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The smoke detectors have not been installed per code.| 165* BE ADVISED. 1) EACH BEDROOM MUST HAVE ITS OWN SMOKE DETECTOR INSIDE. PLEASE MOUNT A MINIMUM OF THREE ( 3) FEET AWAY FROM THE AIR VENT. DO NOT MOUNT CLOSER THAN 6" TO CEILING IF ON WALL AND NOT CLOSER THAN 12" TO WALL IF ON CEILING. 2) MOUNT A SMOKE DETECTOR IN THE SHORT HALL NEAR THE BEDROOMS. WALL OR CEILING OK. COMPLETE WORK AND RECALL THIS INSPECTION. |