Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
03/31/2005 ELECTRIC - FINAL Approved IVRS - Inspection :*
03/24/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :* 1) THIS HOUSE IS VACANT AND FOR SALE- A LICENSED CONTRACTOR IS TO PERFORM WORK. 2) HOOD JUNCTION BOX TO BE GROUNDED AND FILL UNUSED OPENINGS. 3) M/C CABLE TO TERMA?? INTO A FITTING. 4) PLEASE COMPLETE #2 OF PREVIOUS INSPECTION.
03/22/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :* NOT READY CANCELED BY CUSTOMER
02/07/2005 ELECTRIC - FINAL Not ready for Inspection IVRS - Inspection :* 1) JUNCTION BOX REQUIRED FOR SPLICES TO HOOD. 2) PLEASE VERIFY PERMIT FOR SERVICE UPGRADE AND NEW WIRING
01/31/2005 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999* 1) INSTALL J-BOX AT NORTH WEST PORCH FIXTURE ( 2) INSTALL PHYSICAL PROTECTION ( FLEX CONDUIT) AT EXPOSED N.M CABLE ABOVE HOOD ( 3) INSTALL N.M. CONNECTOR WHERE N. M CABLE ENTERS HOOD. 4) FRONT IRRIGATION TIMER IS WIRED IMPROPERLY ( EXPOSED N. M CABLE IS NOT APPROVED BY NATIONAL ELEC. CODE)