Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T05EL00183
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/15/2005 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection :* | |
01/28/2005 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. 50 AMP CIRCUIT BREAKER SHOULD BE A SINGLE PHASE 30 AMP BREAKER 2) OPEN CIRCUIT BREAKER SLOTS TO BE COVERED BY OWNERS OF PARK AT SERVICE PEDESTAL. 3) CORD FROM RV TO PEDESTAL MUST BE LISTED FOR SUCH USE-NOT SPLICED, AND MOLDED CAP. |