Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T05EL00057
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/12/2005 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* APPROVAL OF THIS PROJECT(T05EL00057) DOES NOT APROVE ANY OTHER WORK OF IMPROVEMENT ON THE PREMISES FOR WHICK A PERMIT IS REQUIRED, NOR DOES IT GRANT PROPERTY OWNER AUTHORITY TO CARRY OUT ANY OTHER WORK OF IMPROVEMENT FOR WHICH A PERMIT WOULD BE REQUIRED | |
05/05/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service entrance is not per code.| 215* NO DOCUMENTS ON SITE. |
|
02/01/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service is not per code.| 210* SEE WRITE UP FOR 1743 N WARREN AV ACT # T05EL00057 1743 N WARREN AV NOTES: DENIED 1) THE GROUND CONNECTION TO THE WATER MUST BE LOCATED ON THE HOUSE SIDE PIPE-AHEAD OF THE UNION. 2) WHERE IS GAS PIPE BONDED? 3) WHERE IS DOCUMENTATION, PLANS, AND PERMIT FOR THE SERVICE UPGRADE COMPLETED WITHOUT CITY PERMIT? 4) WHERE IS PERMIT & PLANS FOR APARTMENT ( SOUTH ) WIRING? DO NOT RECALL ANY INSPECTIONS UNTIL ALL THE ABOVE ARE ON SITE. THANKS |
|
01/14/2005 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The service is not per code.| 210* 1) GOUNDING MUST CONSIST OF TWO 5/8" X 8' GROUND RODS, COLD WATER AND GAS PIPING. EXPOSE ENDS OF GROUND RODS 2) THE ELECTRICAL SYSTEM TO 1743 N. WARREN AVE WAS INSTALLED WITHOUT PERMIT 3) WIRING TO REAR UNITS MUST BE DOCUMENTED 4) CONTACT YOUR CONTRACTOR FOR GUIDANCE AND INFORMATION |