Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | VISITED SITE UPON ARRIVAL FOUND A DUPLEX STRUCTURE WITH ADDRESSING IN FRONT OF PORCH BEAM. KNOCKED ON DOORS OF BOTH UNITS, RECIEVED NO ANSWER. HAVE NO CONTACT NUMBER FOR OWNERS, TRIED INFORMATION, THEY HAD NO NUMBER FOR OWNERS ON INTAKE FORM, WILL TRY AGAIN. LEFT "NO ONE HOME" LETTERS ON BOTH UNITS. PICTURES WERE TAKEN. WHEN I RETURNED TO 1015 FOUND TENANT ARRIVING HOME. SPOKE WITH TENANT TRACY CALLED OWNERS ON 19TH CONCERNING TUB BACK UP, CALLED JENA AND JOE CORONA LAND LORDS, HUSBAND OUT OF TOWN, JEN ASKED TENANTS TO USE SOMEONE ELSE'S BATHROOM, SENT SON OVER LATER, SON WENT TO GET A SNAKE NEVER RETURNED ON 20TH TRACY AGAIN HAD SEWER BACK UP. BEEN AT UNIT SINCE JUNE 2004. ELECTRICAL- 1) COVER PLATE NEXT TO SGP TO SWITCHES IS BROKEN 2) COVER PLATE MAY NEED CAULKING 3) NO RECEP IN NORTHEAST BATHROOM 4) JUNCTION BOX NORTHWEST BEDROOM CLOSET HAD BROKEN COVER PLATE 5) HALL BOTH LIGHT AND RECEP=RECEP SHOWS OPEN GROUND AND NO GCFI PROTECTED 6) NORTHEAST BEDROOM FAN CONNECTED TO SQUARE TYPE BOX (NOT UL LISTED) 7) SWITCHES IN HALL IDENTIFY DO THEY WORK ANYTHING 8) RECEPS ABOVE SINK NO GFCI PROTECTED 9) SHOW GERRY SERVICE PANEL INTERIOR FACTORS 1) HINGE ON NORTHEAST BATHROOM LINEN CABINET IS BENT NEEDS REPLACING 2) NORTHWEST BEDROOM WROUGHT IRON DOOR DEAD BOLT DOES NOT LOCK DOOR LOCK AND THRESHOLD ALLOWS DAYLIGHT AND WEATHER ELEMENTS (BOTH EXTERIOR DOORS) 3) DRYWALL UNDER SINK CABINET MISSING NEEDS TO BE COVERED FIRE SAFTEY 1) SMOKE DETECTOR IN NORTHEAST BEDROOM NOT WORKING WORK WITH OUT PERMITS APPEARS BEDROOM TO THE NORTH OF STRUCTURE HAS BEEN ADDED WIDENED BY SGP IN KICHEN AND STEP DOWN. NORTHEAST BATHROOM ADDED STEP DOWN FROM BATH AND KITCHEN TO BEDROOM. WASHER/DRYER ROOM JOINED TO STRUCTURE CEILING AND NORTH WALL UNFINISHED, WIRE IN CEILING LEFT EXPOSED WASHER VENT/DRAIN TIES INTO BOTH. BOTH WASHER ROOM BACK TO BACK. ADDED ELECTRICAL FOR DRYER. PLUMBING 1) RE-SEAL HALL BOTH VANITY TOP (LATEX CAULK) MISSING CAULK 2) RE-SEAL HALL TUB (LATEX CAULK) 3) VANITY FAUCET (HALL) LEAKING FROM BOTTOM OF FAUCET EXTERIOR 1) WINDOWS NEED TRIM TO WEATHER TIGHT SIDING 2) NORTH SIDE OF STRUCTURE HAS ADDED ELECTRICAL BOX/ADDED CIRCUIT 3) ADDED CIRCUIT FOR DRYER 4) ADDED CIRCUIT FOR HEAT PUMP UNIT 103 FROM PORCH ADDED, INADEQUATE BEARING AT BEAM AND TIED INTO FACIA 2x6 RAFTERS 24" OC. 4x6 BEAM BEARING BLOCK WALL ADDED CIRCUIT TO METAL STORAGE SHED |