Case: T05DV00807

Parcel: 122182190

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T05DV00807

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
09/03/2008 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE, RV CARPORT HAS BEEN REMOVED, THIS WAS THE ONLY ISSUE LEFT ON THIS CASE FROM 05 / PERMIT NUMBER T08BU00252 HAS BEEN SECURED AND IS IN ISSUED STATUS
03/14/2006 INSP - FOLLOW UP CODE ENFORCE Correction Required 3/14/06, MEET WITH OWNERS ON SITE, WILLIAM, CATHY, AND AL, CATHY AND AL ARE 1/2 OWNERS, STATES DID NOT KNOW ANY THING ABOUT ISSUES GOING ON, CAME INTO TOWN TO SEE HOW EVERY THING IS GOING, THIS IS HOW THEY FOUND OUT ABOUT NOTICE AND ORDER, CATHY AND AL HAS DONE ALOT OF WORK, UPON ARRIVAL ALL EXTERIOR WORK, CRACKS, STUCCO, AND PAINT HAS BEEN DONE, ALL NON REGISTERED VEHICLES APPOX. 13 HAVE BEEN REMOVED, GARAGE INTERIOR ELECTRICAL STILL NEEDS PERMIT, ADDED CIRCUITS, WATER HEATER P.T.R.VALVE NEEDS REPAIRED TO SHORT.
2) INSTALL NEW WATER HEATER WITH ENCLOSER.
ELECTRICAL SERVICE NOT DONE YET IS SCHEDULED.
SMOKE DETECTOR LOCATED IN WRONG AREA.
4) NEEDS TO RELOCATE SMOKE DETECTOR LOCATED IN WRONG AREA.
6) BEDROOM DOOR NEEDS TO BE PROPERLY SEALED.
RELOCATE SMOKE DETECTOR.
EXTEND HOT WATER TANK PRV.
ELECTRICAL SERVICE NOT DONE YET IS SCHEDULED.
10) REMOVE OLD DETERIORATED WALL FOR PORCH AREA.
REPAIR GATE FOR EASY ACCESS TO MAIN ELECTRICAL METER.
GET PERMITS FOR ADDED BEDROOM, STORAGE SHED, GAS LINES, WATER LINES.
CATHY AND AL AGREED TO HAVE ALL THESE ITEMS ADDRESSED BEFORE 2 WEEKS, WANT TO HAVE DONE BEFORE THEY GO BACK TO WASHINGTON STATE.
03/14/2006 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE, MET WITH OWNERS: BILL CATHY, AL, A LOT OF WORK HAS BEEN DONE, NOT COMPLETED, WALKED EXTERIOR, INTERIOR OF UNITS, WENT OVER ALL UNFINISHED ITEMS. NOTES WERE TAKEN BY DNR AND OWNERS, CATHY AND AL WHO CAME IN FROM WASHINGTON ST. STATED WILL HAVE ALL FINISHED BEFORE LEAVING AND GOING HOME, WENT OVER TIME FRAME, BOTH PARTIES AGREED ON END OF MONTH FOR ALL ITEMS GRANTED EXTENSION FOR APRIL 1, 2006
GARAGE: HOT WATER TANK P&T VALVE TO BE LOWERED
INTERIRO ELECTRIC TO BE PERMITED, ADDED CIRCUITS, OPEN EXPOSED ROMEX
2) REPLACE HOT WATER HEATER(PERMIT)
SEAL FLUE PIPE CONNECTIONS,
ELECTRIC NOT DONE YET.
SMOKE DETECTORS
4) SMOKE DETECTORS
RAIN CAP ON FLUE PIPE.
12/07/2005 INSP - FOLLOW UP CODE ENFORCE Correction Required 12/7/05, VISITED SITE, MET WITH OWNER BILL ON SITE, BILL WAS WORKING INSIDE UNIT #6 TAKING CARE OF ISSUES ON N/O FOR UNIT 6, DID LOOK AT ELECTRICAL SYSTEM AND NOTHING HAD BEEN DONE, BILL IS AN ELDERY GENTLEMAN WHO MISUNDERSTOOD IMPORTANCY OF STARTING WITH ELECTRICAL ISSUES, BILL STATED HE WILL CALL RICK FROM DESERT HILLS ELECTRIC TODAY, I ALSO CALLED RICK FROM DESERT HILLS ELECCTRIC, RICK STATED HE WAS ON NEXT BLOCK AND WILL STOP BY TO GO OVER ISSUES AND SEE WHAT IS NEEDED, RICK SHOWED ON PROPERTY, OWNER ON PROPERTY MYSELF ON PROPERTY, ALL WENT OVER ISSUES, RICK DID STATE THAT HE WILL DO WORK IF BILL AGREES AND HIRES, OWNER STATED YES, WITH CONTRACTOR NOW IN PLACE, GRANTED 30 DAY EXTENSION, RICK STATED HE WILL MAKE CONTACT WITH RICK HOLLANDER (AREA INSP. FOR D.S.D.) AND WILL GO OVER ALL ISSUES TO SEE WHAT DRAWING WILL BE REQUIRED AND GO FROM THERE.
10/10/2005 INSP - FOLLOW UP CODE ENFORCE Correction Required UNIT NUMBER ONE- VISITED SITE TOOK PICTURES.CRACKED WALLS AND STUCCO FALLING OFF.SPOKE TO THE ELECTRIAN FOR WILLIAM OWNER OF UNIT.
TOLD HIM THAT HE NEEDED TO COME ASSESS SERVICE ENTRANCE PER WILLIAM AND EVALUATE WHAT NEEDED TO BE DONE.
THERE IS OVERLOADIND CIRCUITS,JUMPERED WIRING,ELECTRICAL HAZARDS.EXPLAINED TO GILBERT VILLA THAT UNIT NUMBER EIGHT WOULD NEED TO REPAIRED UNDER THE N.O.V. THAT IS GOING TO BE ISSED ON THIS DAY AND THAT IT WAS GOING TO BE ALLOTED FORTY EIGHT HOURS TO ABATE.
EXPLAINED TO GILBERT ALSO THAT WE COULD ONLY GO OVER ISSUES ONLY AND THAT WE COULD NOT REQUEST IT TO BE DONE.
INSPECTED UNIT INSIDE AND FOUND THREE PRONG OULETS-TWO WIRE SYSTEM,NO SMOKE DETECTORS,CRAKED TILE IN SHOWER.TILES MISSING ON KITCHEN COUNTER TOP.
TOLD RICK THAT HE NEEDED TO COME TO THE UNIT AND ASSESS ELECTRICAL SERVICE ENTRANCE AND WHAT NEED TO BE REPAIRED.

UNIT NUMBER TWO-VISITED SITE TOOK PICTURES FOUND NO SMOKE DETECTORS.
LIVING ROOM EAST WALL-OUTLET HAD AN OPEN GROUND.,DINING ROOM HAS AN OPEN GROUND ON OUTLETS,HOT WATER TANK IS RUSTED , AND OLD AND FLU PIPE WAS NOT SEALED ON JOINTS.
SERVICE ENTRANCE WAS TO HIGH,INSULATOR BROKEN,WEATER HEAD BROKEN AND FRAID.
UNIT NUMBER FOUR-VISITED SITE,TOOK PICTURES.
FOUND IN THAT UNIT TREE LEANING SEVERLY,WEATER PROTECTION ON ALL WINDOWS AND DOOORS LACK WEATER STRIPING AND CHALKING.
BROKEN THERMOSTAT TO WALL FURNACE,MISSING GLOBE TO LIGHT FIXTURE IN BEDROOM,NO SMOKE DETECTORS,STORAGE SHED TO CLOSE TO PROPERTY LINE,HOT WATER HEATER FLU PIPE JOINTS NEEDS SEALED,WALLS CRAKED AND STUCCO FALLING OFF UNIT,FOUND CHRISTMAS LIGHTS STILL UP WITH EXTENSION CORD.
UNIT NUMBER SIX-VISITED SITETOOK PICTURES,STARTED INSPECTION AND FOUND SEVERE DELAPIDATION,OPEN WIRING,ILLEGAL HEIGHT ON SERVICE ENTRANC,HAD THREE PRONG OUTLETS IN A TWO WIRE SYSTEM,OPEN GROUND.
OUTSIDE FOUND CRAKED WALLS.INSIDE-LIVING ROOM CONVENINCE WEST WALL OUTLET HAD AN OPEN GROUND.MISSING DOOR STOP,DOOR HAD BARE WOOD EXPOSED TO WEATHER(NO PAINT),MISSING WEATHER STRIPPING FOR DOOR,GAS METER WAS PINNED DUE TO HIGH OF GAS BILL,WALL FURNACE SHOWS HIGH WEAR-LACKS PROPER MAINTANCE,FILTY.
BEDROOM-WEST WALL CONVENINCE OUTLET SHOWS OPEN GROUND,NORTH WALL OUTLET SHOWS OPEN GROUND,EAST WALL OUTLET SHOWS OPEN GROUND,EAST WALL WINDOW HAS BROKEN GLASS.
BATHROOM WINDOW IS BROKEN,FLOOR TILES LIFTING,HOT WATER SIDE OF KITCHEN FAWCET IS LEAKING.
LIVING ROOM-EAST WALL OUTLET SHOWS OPEN GROUND.KITCHEN OUTLETS SHOWS OPEN GROUND.ALL WINDOWS ARE PAINTED SHUT.
UNIT NUMBER EIGHT-VISITED SITE TOOK PICTURES.STARTED INSPECTION FOUND THREE PRONG RECECTICALES ON A TWO WIRE SYSTEM,ILLEGAL WIRING,OPEN WIRING,MAJOR DELAPIDATION,JUMPERED WIRE(BLUE)NO FUSING.
METER ON LEFT -LINES ARE WEATHERED TO THE POINT OF BARE WIRES EXPOSED TO THE ELEMENTS TO CREATE A SAFETY ISSUE.
INSPECTOR JIM HURD HAD SPIKEN TO GILBERT IN REGARDS TO TO THE SERVICE NEEDING UPGRADING.GILBERT STATED THAT HE WOULD HAVE AN ELECTRICIAN OUT IN A COUBLE OF DAYS. INSPECTER J. ORTA HAD STATED TO GILBERT THAT WOULD BE FINE.INSPECTOR J. ORTA TOLD GILBERT THAT THE THIRTY AMP FUSING ISVERY DANGEROUS AND THAT HE NEEDED THE ELECTRICIAN TO COME TO THE UNITS AND EVALUATE TO SEE WHAT NEEDED TO GO GO FROM THERE.
GILBERT THEN ASKED INSPECTOR HURD TO TALK TO OWNER OF UNITS,INSPECTOR J. HURD THEN CALLED HOSPITAL TO TALK TO WILLIAM BUT PHONE WAS BUSY.
INSPECTOR J. ORTA TOLD GILBER TTHAT HE NEEDED A FLOOR PLAN AND WIRING PLAN TO SUBMIT TO D.S.D.
FRONT DOOR IS WEATHERED(BARE WOOD),OVER USE OF POWER STRIPS,POWER GANGS OVERLOADED,WEST WALL OUTLET SHOWS EVERSED POLARITY .
BEDROOM-WEST WALL OUTLET SHOWS REVERSED POLARITY.
REAR DOOR LACKS EGRESS SHOWS LACK OF WEATHER PROTECTION.
BATHROOM- NO ELECTRIC,VENTILATION WINDOW CAN'T GET TO.
TALKED TO TENANT AND TOLD HIM NOT TO CONNECT FUSE BACK IN DUE TO OVERFUSING AND WOULD CAUSE SAFETY ISSUE.
CLOSET HAD SEVERAL ADDED ELECTRICAL CIRCUITS,VENT PIPE FIVE INCH'S NEEDED SEALED AT JOINTS.
KITCHEN HAS THREE PRONG OUTLETS ON A TWO WIRE SYSTEM,OPEN GROUND CIRCUITS,WORN,EXPOSED ROMEX N/W CORNER.
BEDROOM-THREE PRONG OUTLETS SAME CIRCUIT REMOVED FROM COOLER AND BATHROOM.
WROTE N.O.V. STATING THAT HE HAS FORTY EIGHT HOURS TO ABATE THIS ISSUE,HAD GILBERT SIGN AND GAVE WHITE COPY.
UNIT NUMBER TEN-VISITED SITE,TOOK PICTURES,EXTERIOR SHOWS SOME CRAKING,FLUE PIPE FOR WATER HEATER JOINTS ARE NOT SEALED PROPERLY,ROOM ADDED TO SOUTH SIDE.
INSPECTOR J. ORTA ARRIVED ON SITE TO INSPECT SITE.LIVING ROOM NORTH SIDE SHOWS SHOWS OPEN GROUND AOUTLET,ARMOR FLEX THRU RAFTERS ARE OPEN AND EXPOSED,JUNCTION BOX IS OPEN AND HAS TAPED CONNECTIONS,ARMOR FLEX TO TO FAN IN BEDROOM IS EXPOSED ALSO.BEDROOM OULET ON EAST WALL SHOWS REVERSED POLARITY.CLOSET HAS BX CABLEEXPOSED,NORTH BEDROOM APPEARS TO BE ADDED,NO EGRESS DUE TO CANNOT OPEN WINDOW AND IS TOO SMALL.
BATHROOM WATER LINE ADDED,EXPOSED ROMEX,TWO SEPARTE AREAS HAVE EXTENSION CORDS AND EXPOSED BX TO LIGHT FIXTURE.
GILBERT CONTACTED WILLIAM AND HAD INSPECTOR J. HURD TALK TO OWNER WILLIAM.
INSPECTOR J. HURD EXPLAINED TO WILLIAM WHAT NEEDED TO BE DONE,AND TO DISCUSS AT A LATER TIME WHEN ALL N.O.V.'S ARE WRITTEN AND GONE OVER AND EXPLAINED.
WILLIAM STATED THAT HE WAS GOING TO HAVE GILBERT CALL ELECTRICAN AND HAVE ELECTRICAN ABATE ISSUES .
STARTED RE-INSPECTION AT KITCHEN AREA,FOUND IN THIS AREA EXPOSED BX CABLE,EXTENSION CORD FROM JUNCTION BOX TO LIGHT FIXTURE,GAS LINE TO COOK STOVE WAS ADDED,ADDED ELECTRICAL CIRCUITS.
STORAGE SHED ADDED,DETERIORATED,PULLING AWAY FROM WALL,HAS ADDED ELECTRICAL CIRCUITS.
MAJOR DETERIORATION,WALL CRMBLING,ROOF LEAKS,SLATS BROKEN,STRUCTURE HAS CRACKS,STUCCO FALLING OFF WALLS,DOORS OLD AND WEATHERED,FRONT DOOR IS WEATHERED AND NOT WEATHER PROOF.