Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/28/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | SITE INSPECTION FOUND HAZARDOUSLY STRUNG CONDUCT, NOT PROPERLY ANCHORED AND WITHOUT PERMITS ON NORTH BUILDING, EASTSIDE WALL FEEDING TIMER FOR POOL PUMP. 16-13Q3- POOL GATES DO NOT SELF CLOSE OR SELF LOCK. CABLE WITH LOCK ON ONE GATE BUT ALLOWS FOR MORE THAN 4'' GAP. WROUGHT IRON BARS AROUND POOL IS GREATER THAN 4'' HEIGHT FROM GROUND LEVEL TO BOTTOM OF FENCE IS GREATER THAN 2''. 2ND STORY WOOD ON CORRIDOR IS WEAK AND HAS 1'' GIVE IN AREAS. NAILS COMING UP, TRIP HAZARD. SAFETY RAILING NOT PROPERLY ANCHORED. BOLTS MISSING AT CORNERS 5'' TO 6'' SWAY, WITH PRESSURE IT WILL BREAK, ALLOWING FOR PEOPLE TO FALL. WASTENED STEPS CONCRETE BROKEN, READY TO FALL TO GROUND. WOOD STEP ON TOP RUNG NOT SAME AS OTHER. TEMP REPLACEMENT ONLY. |