Case: T05DV00657

Parcel: 13818037A


Addresses:

17 E CORONA RD

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
05/04/2006 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE, MET WITH PROPERTY MANAGER CHARLIE DUVOI AND TENANT MRS VILLEGAS. MRS VILLEGAS WAS HESITANT TO ALLOW ENTRY DUE TO HUSBAND NOT BEING HOME. MR VILLEGAS WOULD ARRIVE LATER, MRS VILLEGAS ALLOWED ENTRY.

UPON RE-INSPECTION OF THE STRUCTURE I FOUND SOME ISSUES STILL HAD NOT BEEN ADDRESSED, OTHER ISSUES WERE ADDRESSED OR ATTEMPTED TO BE DONE. ALL WORK WAS DONE IN A VERY UNWORKMEN-LIKE MANNER AND QUALITY OF THE WORK VERY POOR.

I WILL CONSULT WITH RICK SALDATE ON HOW TO PROCEDE.

MR DUVOI WAS ASKED TO PROVIDE PROOF IN THE WAY OF RECEIPTS FOR ALL WORK COMPLETED.
03/28/2006 INSP - FOLLOW UP CODE ENFORCE Approved VISITED SITE, MET WITH TENANT ROY GALLEGOS. ROY MENTIONED THAT NOT EVERYTHING HAS BEEN ABATED ON THE NOTICE OF VIOLATION. ROY MENTIONED THAT THE PROPERTY MANAGER CHARLIE DUVOI SENT A PEST CONTROL SERVICE ORDER TO TREAT FOR TERMITES, A PLUMBER CAME BY TO MAKE PLUMBING REPAIRS AND ALSO DID SOME VERY MINOR DRYWALL PATCHES. AN ELECTRICIAN ALSO CAME BY TO DO SOME ELECTRICAL REPAIRS. ROY MENTIONED THAT THE PROPERTY MANAGER IS EVICTING HIM FOR NONPAYMENT OF RENT. I ASKED ROY HOW LONG HE HAS LIVED AT THE PROPERTY, HE MENTIONED 2 YEARS, AND HE HAS ONLY BEEN LATE TWICE, THIS PAST TIME HE MENTIONED THAT THE BANK WAS PROVEN TO BE AT FAULT. ROY MENTIONED HE MADE PAYMENT AND THE PROPERTY MANAGER HELD THE CHECK.

I EXPLAINED TO ROY THAT I HAVE BEEN SUBPOENAED TO APPEAR IN COURT FOR FRIDAY 03/30/2006. I MENTIONED I WAS THERE TO CONDUCT A FOLLOW UP INSPECTION AND WOULD REINSPECT EACH ITEM ON THE NOV TO DETERMINE WHAT HAS OR HASN'T BEEN ABATED. MY FINDINGS ARE AS FOLLOWS.

FIRE SAFETY:
1) UNIT LACKING SMOKE DETECTORS: ONE WAS INSTALLED IN THE HALLWAY; PROBABLY NEEDS ANOTHER IN THE DINING ROOM AND LIVING ROOM AREA.

HEATING AND COOLING:
1)COOLER UNDERSIZED OR NOT WORKING: COULD NOT CHECK COOLER AS TENANT MENTIONED IT HAS BEEN DISCONNECTED FOR THE WINTER
2)SOOT COMING FROM SUPPLY REGISTERS, NOT COMPLETED

ELECTRICAL:
CIRCUITS ADDED
(1) IN HOTWATER HEATER ROOM
(1) ADDED FOR WASHER/DRYER
1)PERMITS SECURED?
2)DID LICENSED ELECTRICIAN DO THE WORK?

PLUMBING:
1)TUB WAS NOT RESEALED GAPS EVIDENT BETWEEN TUB AND TILE
2)CRACKED TILE STILL APPARANT ON SOUTHERN WALL AND BROKEN TILE ON SOUTHEASTER CORNER OF TUB (HALL BATH)

INTERIOR FEATURES:
1)KITCHEN DOOR HAS NOT BEEN CORRECTED
2)KITCHEN CEILING DRYWALL HAS NOT BEEN REPAIRED, BUCKLING AND CRACKING STILL APPARENT IN AREA NEXT TO BEAM.
3)KITCHEN WALL AROUND THE STOVE IS SATURATED WITH GREASE. IF PAINTED IT WOULD NOT BE IN THIS CONDITION
4) APPEARS THAT THE LIVING ROOM IS STILL LEAKING AT THE BEAM BETWEEN THE DINING ROOM AND LIVING ROOM EVIDENCED BY THE WATER SPOTS ON THE POPCORN CEILING.
5)CEILING IN HOTWATER HEATER ROOM HAS NOT BEEN PROPERLY REPAIRED.
6)HALL CLOSET DOORS STILL LACK DOOR PULLS
7)SOUTHWESTER CORNER OF MASTER BEDROOM APPEARS TO STILL BE LEAKING.
8)CLOSET DOORS ALL OFF TRACKS. NORTHEASTERN BEDROOM DOOR IS ALSO CAUGHT ON CARPET, NEEDS TO BE CUT FOR LENGTH
9)TENANT MENTIONED THAT THE STRUCTURE HAS BEEN TREATED. NONE OF THE BASE BOARD HAS BEEN REPLACED OR REPAIRED.

WILL CHECK WITH JERRY ORTA ON ELECTRICAL