Case: T05DV00657

Parcel: 13818037A


Addresses:

17 E CORONA RD

Inspection Status: Closed

Inspection History: INSP - INITIAL CODE ENFORCMENT

Date Description Inspector Results Comments
08/07/2006 INSP - INITIAL CODE ENFORCMENT Closed REVISITED SITE AFTER TENENT HAD MOVED OUT. PROPERTY MANAGER CHUCK DUVOI ALLOWED ENTRY. FOUND THAT ALL VIOLATIONS HAD BEEN ABATED BY MR. DUVOI. THERE WAS NO EVIDENCE OF CEILING LEAKING. COOLER SEEMED TO BE WORKING PROPERLY. BATHROOMS HAD BEEN CLEANED, VINYL AND TOILETS REPLACED, SHOWER AND TUB HAD BEEN CLEANED AND REGROUTED. BASEBOARD HAD BEEN REPLACED. ENTIRE INTERIOR HAD BEEN REPAINTED. A/C CEILING HAD BEEN DRYWALLED. KITCHEN COUNTER TOP REPLACED. WINDOW SCREENS HAD BEEN REPLACED, AS WELL AS NEW WINDOW TREATMENTS (BLINDS). ALL DOORS HAD BEEN REPLACED OR REHUNG. TWO SMOKE DETECTORS HAD BEEN ADDED. PICTURES WERE TAKEN. DNR HAS NO FURTHER ISSUES. CASE CLOSED.
09/23/2005 INSP - INITIAL CODE ENFORCMENT Approved VISITED SITE, MET WITH TENANT ROY VILLEGAS. ROY MENTIONED THAT AFTER MOVING INTO UNIT FOUND FOUND CERTAIN PROBLEMS OR ITEMS THAT LOOKED LIKE THEY HAD BEEN REPAIRED BUT NEVER FINISHED IE. THE DRYWALL. HE MENTIONED THAT THE COLLER HAD NOT BEEN WORKING, COULD NOT GET OWNER TO REPAIR IT AND ENDED UP INSTALLING A/C UNITS INSIDE THE STRUCTURE. A VERBAL AGREEMENT WAS MADE TO INSTALL A CHAINLINK FENCE IN THE FRONT YARD, MR VILLEGAS HAD THAT INSTALLED HIMSELF. A LETTER WAS SENT TO THE OWNER BY THE TENANT WITH A LIST OF ITEMS THAT NEEDED REPAIRS. THE LIST OF ITEMS HAS GROWN. I EXPLAINED TO MR VILLEGAS THAT I WOULD BE CONDUCTING A MINIMUM HOUSING INSPECTION AND HOW THAT WORKED. MR VILLEGAS ALLOWED ENTRY, MY FINDINGS ARE AS FOLLOWS:
FIRE SAFETY:
>UNIT LACKS WORKING SMOKE DETECTORS
ELECTRICAL:
>KITCHEN RECEPTACLES (2) WITHIN 6 FEET OF KITCHEN SINK ARE NOT GFCI PROTECTED.
>KITCHEN LIGHT NOT COMPLETED, LACKS LIGHTS AND BULBS.
>RECEPTACLE IN MASTER BEDROOM NEXT TO BATHROOM DOOR SHOWS HOT AND NUETRAL WIRES ARE REVERSED.
>ELECTRICAL BOX IN HOTWATER HEATER ROOM LACKS COVER
>A CIRCUIT HAS BEEN ADDED FOR THE OUTLET AND LIGHT IN HOTWATER HEATER ROOM.WORK WITHOUT PERMITS!
>CIRCUIT HAS BEEN ADDED FOR WASHER/ DRYER.

HEATING AND COOLING:
>APPEARS COOLER IS NOT WORKING PROPERLY EVIDENCED BY THE SMALL AMOUNT OF AIR BEING PUSHED OUT OF THE REGISTER.
>BLACK SOOT IS BEING PUSHED OUT OF THE REGISTERS EVIDENCED BY THE SOOT ABOVE MOST OF THE SUPPLY REGISTERS THROUGHOUT THE STRUCTURE.

PLUMBING:
>BATHROOM VANITY NOT PROPERLY SECURED TO THE WALL.
>TUB FAUCET OR WATER FIXTURES APPEAR TO BE LEAKING EVIDENCED BY THE WATER STAINS BELOW THE FIXTURES, AND ESCUCHEONS DO NOT COVER THE OPENING IN TILE AND MUST BE SEALED.
>TUB NEEDS TO BE RESEALED AT ALL EDGES OF TUB AND TILE AND SOAP HOLDER. CRACKED TILES NEED TO BE REPAIRED.

INTERIOR FEATURES:
>INTERIOR DOOR NOT SEALED AT TOP, SHOW A 1/2" GAP.
>ROOF APPEARS TO BE LEAKING, EVIDENCED BY THE SAGGING DRYWALL CEILING AROUND THE BEAM AREA.
>APPEARS WALL THROUGHOUT THE STRUCTURE HAVE BEEN RETEXTURED AND NEVER SEALED BY PAINTING.
>APPEARS TO BE ROOF LEAKS IN THE LIVING ROOM AREA EVIDENCED BY THE WATER SPOTS ON POPCORN CEILING.
>HOTWATER HEATER ROOM DOUBLE DOOR DOES NOT CLOSE PROPERLY DUE TO DOORS BEING TOO TIGHT.
>CEILING IN HOTWATER HEATER ROOM IS DETERIORATING, DRYWALL CRACKED AND BROKEN, AND DRYWALL TAPE PULLING AWAY FROM THE DRYWALL.
>HALL CLOSET DOORS DO NOT CLOSE PROPERLY, DOORS TOO TIGHT AND RIGHT DOOR LACKS A DOOR PULL (OR KNOB)
>APPEARS TO BE ROOF LEAK IN NORTHWEST BEDROOM EVIDENCED BY POPCORN CEILING BLISTERING AGAINST THE BLOCK WALL, WEST SIDE.
>APPEARS CEILING IN NORTHEAST BEDROOM IS EITHER LEAKING OR HAS BEEN LEAKING EVIDENCED BY THE PATCHES ON THE CEILING.
>CLOSET DOOR IN NORTHEAT BEDROOM IS DETERIORATING EVIDENCED BY DOOR SKIN PEELING AWAY FROM THE DOOR.

RODENT CONTROL:
THERE APPEARS TO BE A TERMITE INFESTATION EVIDENCED BY DETERIORATED BASEBOARD IN HALL AREA NEAR THE KITCHEN AND "SPOTTED" AREAS THROUGHOUT THE HALL WAY. BASEBOARD APPEARS EATEN BY THE TERMITES.