Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T05DV00604
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | MET WITH MAINTANENCE PERSON OSCAR WHO MENTIONED THAT A/C IN UNIT 2167 HAD BEEN REPAIRED TO BEST OF HIS KNOWLEDGE. IT HAD BEEN MENTIONED TO ME IN THE PAST BY MANAGER DEBBIE BERNARDI THAT TENANT HAD BEEN ACCUSED BY THE A/C MAINTANENCE PERSON OF TAMPERING WITH THE A/C UNIT. MET WITH ELOISA GOMEZ, WHO MENTIONED THAT THAT A/C PEOPLE HAD BEEN OUT TO FIX THE A.C BUT THAT WORK HAD NOT BEEN COMPLETED.ELOISA TRIED TO EXPLAIN TO ME WHAT WORK REMAINED TO BE DONE TO THE A/C UNIT BUT EXPLANATION MADE NO SENSE.(WILL FOLLOW UP WITH A/C MAINTANENCE COMPANY) WHILE INSPECTING THE A/C TENANT MENTIONED THAT SHE ALSO HAD SEVERAL OTHER VIOLATIONS, COULD I TAKE A LOOK. I EXPLAINED THAT I WOULD BE CONDUCTING A COMPLETE INSPECTION OF THE UNIT. WENT OVER WITH TENANT HOW INSPECTION WOULD BE CONDUCTED.MY FINDINGS ARE AS FOLLOWS: ELECTRICAL: > LIVINGROOM RECEPTICLE LACKS COVER PLATE AND IS NOT WORKING. SECOND RECEP IS NOT PROPERLY MOUNTED(LOOSE IN WALL) >KITCHEN RECEPTICLE WITHIN 3' OF SINK LACK GFCI PROTECTION. >SOUTH BATH RECEP NOT GFCI PROTECTED. PLUMBING: >(TUB STOPPER) SHOWER CONVERTER NOT WORKING PROPERLY. >WATER LEAKING FROM THE BOTTOM OF TUB NEAR THE TOILET. >TUB NEEDS TO BE CAULKED ALONG THE PERIMETER OF TILE, TOP OF TUB. INTERIOR FEATURES: >DOOR TO HOTWATER HEATER SPACE IS OF ITS TRACK. >KITCHEN SINK BASE CABINET, AND CABINET TO THE LEFT OF STOVE HAVE DETERIORATING WOOD FLOORS. >KITCHEN CABINET NEXT TO STOVE MISSING A DRAWER. >CEILING IN NORTH BEDROOM LEAKING, EVIDENCED BY WET POPCORN CEILING. >WINDOW SCREEN IN NORTH BEDROOM MISSING. >BIFOLD DOORS ARE OFF THE TRACK IN SOUTH BEDROOM. >WINDOW LOCK IN SOUTH BEDROOM NOT WORKING. >LIVINGROOM DOOR IS OFF ITS TRACK DUE TO DOOR RUBBING ON CARPET. >CEILING OUTSIDE OF FRONT DOOR IS ALSO LEAKING. >HOLES IN DRYWALL THROUGHOUT THE UNIT NEED PATCHING. > REPLACE ALL A/C GRILLES. AFTER INSPECTION, I MET WITH OSCAR BACK AT THE OFFICE, AT WHICH TIME AL FROM ARIZONA MAINTANENCE SHOWED UP. ASKED AL IF HE WAS FAMILIAR WITH UNITS 1168 AND 2167, HE SAID THAT HE HAD BEEN TO BOTH UNITS, AND DID HAVE MAINTANENCE REQUEST FORMS WITH HIM. AT 2167 HE SAID HE HAD BEEN THERE ON SEVERAL DIFFERENT OCCASIONS. ALSO MENTIONED THAT HE FELT TENANT WAS TAMPERING WITH A/C UNIT AND EVERY TIME HE WENT BACK TO THE APT. GRILLES HAD BEEN REMOVED. AL MENTIONED THAT THE CONDENSOR WAS BLOWN, BUT ALREADY INSTALLED A NEW UNIT. AL ALSO MENTIONED HE HAD TO REPLACE OTHER PARTS, THAT IF MAINTANENCE HAD PARTS IN AN UNOCCUPIED UNIT HE COULD SWAP OUT PARTS TODAY. OSCAR, APT MAINTANENCE, SAID HE COULD. LATER SPOKE WITH DEBBIE BERNARDI 8/10/05 WHO MENTIONED SHE WOULD LIKE TO HAVE A RE-INSPECTION ON FRIDAY AS WORK HAD ALREADY BEEN STARTED AND DEBBIE FELT WOULD BE COMPLETED ON FRIDAY. PICTURES WERE TAKEN. WILL SCHEDULE FOLLOW UP. |