Inspection History Details
Inspection Status: Approved
Inspection History: NPO - SMOKE ALARMS
Case Number - T05DV00582
Inspection Description - NPO - SMOKE ALARMS
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/16/2005 | NPO - SMOKE ALARMS | Approved | PRIOR TO VISITING SITE, I MADE CONTACT WITH OWNER JAN CASEY. I WENT OVER PROBLEMS (17) ON COMPLAINT FORM. JAN MENTIONED THAT WHEN SHE IS CONTACTED ABOUT ANY PROBLEMS THAT WHE TRIES TO TAKE CARE OF THEM QUICKLY. LAST TIME SHE WAS CONTACTED, SHE HAD A FRIEND OF THE TENANTS MAKE THE REPAIRS AND SAID SHE PAID APPROX. $100.SHE SAID AS OF LATE SHE HAD NOT RECEIVED ANY CALLS. ASKED IF WHE WISHED TO BE PRESENT FOR INSPECTION, SHE ASKED TO PLEASE CALL HER AFTER I COMPLETED THE INSPECTION. MENTIONED THAT I COULD GET HER A LIST SO THAT SHE COULD BEGIN REPAIRS. VISITED SITE, MET WITH TENANT CORINA GARCIA, WHO MENTIONED THEY HAD BEEN CALLING AND CALLING THE LANDLORD AND COMPLAINING ABOUT THE REPAIRS BUT THAT NOTHING HAD GOTTEN DONE. CORINA MENTIONED THAT ANY MINOR REPAIRS WERE TAKEN CARE OF BY THEIR FRIENDS. ASKED TENANT IF THEY ARE CURRENT ON RENT, SHE SAID THAT THEY WERE CURRENT BUT OWED SOME MONEY FOR AUGUST RENT. CORINA MENTIONED THAT THEIR LEASE HAS EXPIRED AND THAT THEY ARE MONTH TO MONTH AT THIS TIME. SHE ALSO MENTIONED THAT BECOAUSE OF NOTHING GETTING DONE THEY MAY MOVE OUT. ENTERED THE STRUCTURE AND FOUND THAT TENANTS WERE ALREADY BOXING THEIR BELONGINGS, BED IN NORTHEAST BEDROOM HAD ALREADY BEEN TAKEN DOWN.VIEWED BOXES IN NORTHWEST BEDROOM( KIDS ROOM). THERE WERE SEVERAL MINIMUM HOUSING VIOLATIONS, MY FINDINGS ARE AS FOLLOWS: INTERIOR FEATURES: >WINDOW CRANKS THROUGHOUT THE STRUCTURE EITHER LACK OR ARE MISSING WINDOW CRANKS. WINDOWS ARE PAINTED SHUT MAKING IT DIFFICULT TO OPEN WINDOWS AND WINDOW LATCHES. >GLASS PANE IN DININGROOM WINDOW SEVERELY CRACKED >KITCHEN CABINETS AND HALL CABINETS BOTH LACK OR HAVE BROKEN DOOR CATCHES. DOORS DO NOT PROPERLY CLOSE OR DOORS STAY OPEN DUE TO CABINETS BEING PAINTED LEAVING DOORS TOO TIGHT TO CLOSE. >CRACK IN KITCHEN CEILING NEEDS TO BE REPAIRED.(TENANT MENTIONED IT LEAKS, HOWEVER NO WATER STAINS WERE VIEWED.) >HOT WATER HEATER DOOR LACKS A KNOB. >KITCHEN COUNTER TOP NEXT TO THE STOVE IS NOT PROPERLY MOUNTED. >FLOOR TILE UNDER REFRIGERATOR IS DAMAGED(1) NEEDS REPAIRING. >HOLE IN FURNACE ROOM WALL NEEDS PATCHING. >TOWEL BAR AND TOILET PAPER HOLDER HAS COME OFF THE WALL NEEDS TO BE REPLACED OR REMOVED AND HOLES PATCHED. >BOTH BEDROOM DOORS DO NOT SHUT, NEED TO BE TRIMMED. >NORTHEAST BEDROOM DOOR LACKS A DOOR KNOB. >LARGE HOLE NEXT TO ELECTRICAL PANEL NEEDS PATCHING OR SOME TYPE OF COVER PLATE. >NORTHWEST DOOR KNOB NOT PROPERLY WORKING. FIRE SAFETY: UNIT LACKS WORKING SMOKE DETECTORS (2). ELECTRICAL: >DININGROOM SWITCH LACKS COVER PLATE. >DININGROOM FAN WOBBLES SEVERELY, AS WELL AS NORTHWEST BEDROOM FAN. >ELECTRICAL BOX IN FURNACE ROOM NEEDS TO BE CORRECTLY MOUNTED. >COMPLETE OVER HEAD VANITY LIGHT IN BATHROOM OR REMOVE. >ELECTRICAL BOX IN NORTHWEST BEDROOM CLOSET LAKS COVER PLATE. > |