| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2005 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 8/4/05, EMERGENCY CALL BY INSP. 2 RICK AND AMINAL CONTROL. INSP ORTA ASSISTED, SPANISH SPEAKER, VISITED SITE, TOOK PICTURES, MET WITH AMINAL CONTROL JANE LUNDY. UPON ARRIVAL OCCUPANT WAS NOT AT DWELLING, HAD MADE APPT. WITH AMINAL CONTROL, WHILE KNOCKING ON DOOR A GENTLEMAN LEFT OUT THE BACK DOOR, INSP ORTA FOLLOW TO TALK WITH HIM, GENTLEMAN STATED HE AND HIS WIFE AND DAUGHTER STAY IN REAR ROOM, ALL 3 WERE ON SITE, AT THIS TIME OWNER OF DWELLING WAS LOCATED IN MOBILE HOME PARK TRYING TO AVOID. SHE DID RETURN TO DWELLING, AMINAL CONTROL WAS ACCESSING CAT ISSUE, ALOT OF CATS RUNNING AROUND. WEST SIDE OF MOBILE HOME EXTERIOR FULL OF TRASH AND DEBRIS, CAT FOOD CONTAINERS, SHOPPING CARTS, REFRIGERATORS, ONE IS BEING USED, OTHER NOT, COOLER DETERIORATED, STAND DETERIORATED, TREE BY FRONT DOOR IMPEDES WALK WAY AND OPENING OF DOOR, ADDITION ADDED TO NORTH END OF MOBILE HOME, LOCKED CAN NOT ENTER. DID AT THIS TIME GO INTO DWELLING, MOBILE HOME HAS BEEN PARTITIONED OFF IN 1/2, RENTING NORTHEND OF DWELLING TO ANOTHER FAMILY, THIS AREA INCLUDED 2 ROOMS AND BATHROOM, ONE ROOM BEING USED AS BEDROOM, LACKS EGRESS, SMOKE DETECTOR, HAZARDOUS ELECTRIC ISSUES, OPEN AND EXPOSED ELECTRICAL CONDUCTORS HANGING OUT OF CONVENIENCE OUTLETS, LIGHT SWITCHES, AND LIGHT FIXTUES, HAZARDOUS SPLICES, USING WRONG WIRING FOR CONNECTIONS, USING EXTENSION CORDS IN LIEU OF PERMANENT WIRING, POWER STRIPS WITH SEVERAL CONNECTIONS, TRASH AND DEBRIS SCATTERED ABOUT MAKING IT HARD TO NAVIGATE, CREATING FIRE HAZARDS, BATHROOM SINK CAN NOT BE ACCESSED DUE TO TRASH AND DEBRIS, TOILET ACCESSABLE BUT DOES NOT FLUSH PROPERLY HAVE TO FLUSH SEVERAL TIMES BEFORE WASTE IS REMOVED, FLOOR WEAK AND SPONGY DUE TO WATER LEAKS BY TOILET, TUB ACCESSABLE, SHOWER WALL PROTECTIVE COVERINGS DETERIORATED AND ALLOWS WATER TO ENTER IN BEHIND AND DETERIORATE STRUCTURE, HAS HOLES BY DEVERTER, HAZARD ELECTRICAL CONNECTIONS,SPLICES, WRONG SIZED WIRING BEING USED FOR ELECTRICAL CONNECTIONS, OPEN AND EXPOSED ENERGIZED CONDUCTORS IN SEVERAL AREAS, LIGHT SWITCH AND FIXTURES, MISSING PROTECTIVE COVER PLATES, HALLWAY, EXPOSED ELECTRICAL CIRCUITS, ADDED CIRCUITS, ENERGIZED WIRING STICKING OUT OF BOXES, MORE EXTENSION CORDS BEING USED, HALLWAY TRASH AND DEBRIS STACKED FROM FLOOR TO CEILING WITH ONLY APPOX 1-1/2 FEET IN WIDTH TO MOVE AROUND FROM ROOM TO ROOM AND TO GET TO EGRESS DOOR, 2ND ROOM, BEDROOM, LACKS EGRESS, SMOKE DETECTOR, MORE HAZARDOUS ELECTRICAL CONNECTIONS, EXTENSION CORDS BEING USED, POWER STRIPS, OVER LOADING OF ELECTRICAL SYSTEM, EXPOSED ENERGIZED ELECTRICAL CONDUCTORS, TRASH AND DEBRIS SCATTERED ABOUT, FRONT HALF OF MOBILE HOME, THIS AREA PACK FROM FLOOR TO CEILING IN ALL OF FRONT AREA APPOX. 12X30, CAN ONLY ENTER FROM DOOR APPOX. I FOOT INWARD AND APPOX 4 FEET GOING SOUTH REST NOT ACCESSABLE, CLOTHES, PAPER GOODS, BOXES FOOD, FOOD CONTAINERS EMPTY AND FULL, MORE EXTENSION CORDS BEING USED, COULD NOT FOLLOW EXTENSION CORDS DUE TO ALL THE TRASH AND DEBRIS, COMPLETE MOBILE HOME FIRE HAZARD, CITY DEEMS DWELLING UNFIT TO OCCUPY, SHUT DOWN DWELLING DUE TO HAZARDOUS ELECTRICAL, HAZARDOUS OVER ACCUMULATION OF TRASH AND DEBRIS, LACK OF PROPER EGRESSES IN CASE OF FIRE OR PANIC. BEFORE LEFT SITE, DISCONNECTED ELECTRICAL SERVICE, TURNED OFF MAIN BREAKER, AND PULLED LIFE LINE CORD, NOT TO BE REENERGIZED UNTIL ELECTRICAL HAZARDS HAS BEEN CORRECTED, UNDER PERMIT. |
|
| 08/04/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | 16-11 1 (1,2,3) FIRE SAFTEY, WINDOWS COVERED WITH BOARDS, DWELLING LACKS EGRESS IN CASE OF FIRE OR PANIC, DWELLING LACKS SMOKE DETECTORS. 16-11 C (1,2) ELECTRICAL SYSTEM, EXPOSED ENERGIZED WIRING STICKING OUT OF ELECTRIC BOXES, CONVENIENCE OUTLETS, LIGHTS SWITCHES AND LIGHT FIXTURES, UNDER SIZED WIRING TO HOT WATER TANK, UNDER SIZED WIRING HOT TO THE TOUCH, TO MANY AMPS THROUGH WIRING, HAZARDOUSLY USING EXTENSION CORDS IN LIEU OF PERMANENT WIRING. REPAIR PERMIT REQUIRED 16-11 G (1) INTERIOR SANITIATION: DWELLING HAS HAZARDOUSLY OVER ACCUMULATION OF TRASH, DEBRIS, TO INCLUDED CLOSTHING, DRY PAPER GOODS, BOXES, EXCESSIVE COMBUSTABLES, MAJOR FIRE HAZARDS IF ANY WIRES WERE TO TOUCH TOGETHER WOULD CAUSE SPARKS. |
|
| 08/04/2004 | INSP - INITIAL CODE ENFORCMENT | Approved | NORTH BEDROOM; CEILING FAN WITH ZI CORD OPEN FAN AT WALL CORDS THROUGHOUT ILLEGAL ADDITION (12x12?) NO S.D. A/C 4.8 AMPS-POWER CORD IN STANDARD RECEP. NO FIXTURE COVER WALL MULTIRECEPT ADAPTER BATHROOM; TOILET DOES NOT OPERATE-NO FLOW BATH LIGHT COMES ON WITH HALL SWITCH, SALL SWITCH IN OPEN ADN EXPOSED, SURFACE ZIP CORD INTO BATHROOM, EXPOSED WIRING OF CEILING BOX, INPROPER SPLICES, ILLEGAL INSTALLATION OF BATH CEILING FIXTURE-NO FIXTURE INSULATION EXPOSED OPW ABANDONED SWITCH BOX AT TOILET WALL-ENERGIZED VANITY AREA; 2 EXPOSED CEILING JUNSTION BOXES W/IMPROPER SPLICING OPEN WIRING AND TAPED SHOWER SURFACE WORN, ROUGH, MOLD, NO SEAL AT TUB SURROUND- NO WINDOW AT BATHROOM HALLWAY; LIGHT REMOVED, EXPOSED WIRES AND A/C UNIT OPEN SPLIC, WIRED PERMANENTLY WITH EXTENSION CORD *12" OF ISLE-WAY N. 1/2 SOUTH BEDROOM; NO SMOKE DETECTOR 1 CEILING FIXTURE MISSING A/C WITH 2 INCH CORD AT EAST WALL, USING EXTENTION CORD CIRCUIT SPLITTED BEING USED AND CORD PLUGGED INTO IT *UNIT IS SPLIT IN 2 UNITS WALL INBETWEEN SOUTH 1/2 OF UNIT; PACKED FROM FLOOR TO CEILING WITH INTRA WALKWAY 5'x1 12' WIDE 12 WIDE x27' LONG HAD TO GO TO SOUTH END TO COMPLETE INTERIOR INSPECTION EXTERIOR EAST; WINDOWS BOARDED UP (3) WATER HEATER ELECTRIC- EXPOSED WIRING VM RAIN TIGHT P+T VALAUE UP 5' AND DISCHARGE HORIZONTALLY AWAY FROM TRAILOR HEATER STANDING ON GROUND #10 AL BAILING WIRE AS EQUIPMENT GROUND ACCESS RESTRICTED TO WATER HEATER 6/4 S.O. CORD ENTERING UNIT (LIFE LINE) HANGING ON SHARP EDGE NORTH EXTERIOR; 10x12 SHED ADDED HAPHAZARDLY WITH DETERIORATING PARTICAL BOARD, NO PERMITS, SET DIRECTLY ON GROUND WEST EXTERIOR; PEDISTAL NOT LABELED, POWER BOX PULL OUT BY PRONGED, UNSING ADJACENT BOX ON A 2 POLE 50 BREAKER NO GROUNDING ELECTRIC VISIBLE PROTRUDING WATER SPIKETT IN FROM OF SERVICE * NOTE* THERE IS ANOTHER METER AND DISCONNECT FROM WEST TRAILOR THE 22' EASEMENT INBETWEEN UNITS FROM A 4 TO 1' PATHWAY, THE REMAINDER IS STREWN WITH ALUMINUM CANS, CARPETS, WOOFER, T.V.'S, CLOTHING, TRASH ANS A LARGE DESERT BROOM. STILL NEED TO SEE THE STORAGE ROOM. THE STAIRS ARE BLOCKED ON THE NORTH AND HAPHAZARDLY WORK ON THE SOUTH. PLUGGED IN REFRIGERATOR STAIRWELL RESTRICTED BY DESERT BROOM 12'HIGH |