Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case: T05DV00390

Parcel: 116161540


Addresses:

1011 N ANITA AV

Inspection Status: Correction Required

Inspection History: NPO - SMOKE ALARMS

Date Description Inspector Results Comments
05/27/2005 NPO - SMOKE ALARMS Correction Required 5/25/05, VISITED SITE, TOOK PICTURES, COULD SEE FROM ROAD WAY DWELLING HAS BEEN RED TAGGED FROM T.E.P. DWELLING LACKS REQUIRED ELECTRICAL SERVICE. KNOCKED ON FRONT DOOR SEVERAL TIMES NO ONE ANSWERED. INSP. VIDAL WENT AND KNOCKED ON REAR DOOR, FEMALE MONICA ANSWERED, I ASKED ABOUT ELECTRIC MONICA STATED THAT ELECTRIC HAS BEEN TERMANATED APPOX. 3 WEEKS AGO, LIVED IN DWELLING FOR ABOUT 2 YEARS PAYS 300.00 A MONTH, I EXPLAINED DUE TO LACK OF ELECTRICAL SERVICE I WILL BE SHUTTING DOWN HOUSE, RESIDENTS USING CANDLES FOR LIGHT, LACKS ANY TYPE OF COOLING,
WENT THROUGH PROCESS AND EXPLAINED TO MONICA, MONICA UNDERSTOOD, ALSO DONE COMPLETE INSPECTION AT THIS TIME,
EXTERIOR:
FOUND SEVERAL ISSUES IN NEED OF REPAIR,
NO ELECTRIC SERVICE AT METER,
NO WATER BOND OR GAS BOND FROM METER,
GAS METER HAS BEEN REMOVED,
COOLER STAND MADE OF WOOD DETERIORATING,
EXTERIOR SHOWS SEVERAL STRUCTURAL CRACKS,
FRONT DOOR HAS BROKEN WINDOW, MISSING, COVERED WITH A RUG,
ALL FACIA BOARDS DETERIORATED LACKS PROTECTIVE COVERINGS.
ROOF SHOWS DETERIORATION SAGGING.
CONTINOUSLY LEAKS FROM BEHIND STUCCO ON SOUTHWEST SIDE OF STRUCTURE.
HOT WATER TANK HAS BEEN REPLACED TO ELECTRIC, LACKS PROPER P.R.V. DRAIN LINE, PERMIT ISSUED BY NEVER FINALED. T03PL00601.
WATER SUPPLY LINES REPLACED TO COPPER NO PERMIT.
4" SEWER LINE OPEN LACKS CAP.
INTERIOR:
NO SMOKE DETECTORS IN ALL ROOMS.
3-PRONG CONVENIENCE OUTLETS SHOWING OPEN GROUND UNDER TEST.
STRUCTURE CRACKS INTERIOR.
EXTERIOR DOOR HAS DOUBLED KEYED DEAD BOLT INSTALLED.
COOLER DETERIORATED TO A POINT OF NOT OPERATING, RUSTED, BEARINGS DETERIORATED, SQUIRREL CAGE DETERIORATED.
DINING ROOM BROKEN OUTLETS.
FRONT DOOR LACKS WEATHER PROTECTION.
KITCHEN MISSING ALL ELECTRICAL COVER PLATES,
COOK STOVE DOES NOT OPERATE.
DOOR LACKS WEATHER PROTECTION.
WINDOW BROKEN.
WATER SUPPLY LINES HAS BEEN REPLACED.
TOILET CONTINOUSLY RUNS.
PLASTER WALLS IN BATH DETERIORATED AND PLASTER FALLING FROM WALLS EXPOSING ADOBE STRUCTURE.
COMPLETE SHOWER AREA HAS BEEN ADDED WITH SUPPLY LINES AND DRAIN LINE.
BATHROOM LACKS BATH SINK SEWER LINE OPEN.
TERMITE DAMAGE IN BATHROOM.
CALLED OWNER ROY ROMERO 648-2624 EXPLAINED ISSUES TO ROY HE STATED HE IS GOING TO HAVE OCCUPANTS MOVE, I EXPLAINED TO ROY THAT IF HE VACATES STRUCTURE I WILL BE PUTTING A HOLD ON ELECTRICAL POWER SO HE WOULD NOT BE ABLE TO RERENT UNTIL ISSUES HAS BEEN CORRECTED, I HAD A CASE ON SAME PROPERTY APPOX 2 1/2 YEARS AGO ROY STATED HE WOULD NOT BE RENTING STRUCTURE AT THIS TIME UNTIL HE FIXES UP STRUCTURE HE DID IN FACT RERENT. EXPLAINED TO ROY WOULD BE SENDING A NOTICE AND ORDER AND ALSO I WOULD BE SHUTTING DOWN STRUCTURE AT THIS TIME DUE TO LACK OF ELECTRICAL SERVICE.
DONE EMERGENCY VACATE N/O ON SITE POSTED DWELLING UNFIT TO OCCUPY, SIGNED BY RESIDENT MONICA.
NOTICE AND ORDER TO FOLLOW.