06/09/2005 INSP - INITIAL CODE ENFORCMENT Approved 6/09/05 MET WITH TENANTS LAURA SHARPLEY AND SGNIFICANT OTHER TIM, PRESENT OCCUPANTS OF THE STRUCTURE AT THIS TIME. AND FROM DEED AND NOTE TRADERS, ROY (MAINTANENCE) AND KELLI. TENANTS EXPLAINED THAT THEY HAV E LIVED AT PROPERTY FOR APPROX 1YR, MENTIONED THAT 0N 6/08/05 THEY HAD GONE TO COURT AND BASICALLY DEED AND NOTE TRADERS DISMISSED ANY CHARGES AGAINST TENANTS, WAIVED LAST TWO MONTHS OF RENT AND ALLOWED TENANTS TO BREAK CONTRACT. KELLI MENTIONED THAT AT THIS POINT THEY JUST WANTED TENANTS OUT OF THE STRUCTURE. KELLI MENTIONED THAT TENANTS HAVE TO THE END OF MONTH TO MOVE OUT. KELLI MENTIONED THAT ONCE TENANTS HAVE MOVE OUT, THEY WILL COME IN AND REHAB THE UNIT, AND MAKE MOVE IN READY OR SELLABLE. ROY MENTIONED THAT THEY HAD COMPLETELY GUTTED THE STRUCTURE AND REMODELED IT PRIOR TO TENANTS MOVING IN, LAURA AND TIM REITERATED WHAT HAD BEEN SAID. KELLI MENTIONED THAT THEY WOULD WAIT TO RECEIVE NOV AND USE THAT AS A GUIDE LINE TO REMODEL UNIT. EXPLAINED TO BOTH TENANTS AND DEED AND NOTE TRADERS HOW INSPECTION WORKED, AND AFTER I WOULD BE ISSUING AN NOV. MY FINDINGS ARE AS FOLLOWS:
ELECTRICAL (EXERIOR)
>WASHERL/DRYER OUTLETS HAVE BEEN ADDED, WORK W/O PERMITS.
>220 FOR SPA HAS BEEN ADDED ILLEGALLY.
>ADDED SWITCH AND OUTLET HAS BEEN ADDED.
>MOTION DETECTOR LIGHT AT BACK PORCH HAS BEEN ADDED
>OUTLET UNDER THE ORIGINAL EVE AT BACK PORCH HAS BEEN ADDED.
>LIGHT BOX AT REAR DOOR IS NOT PROPERLY WIRED, WIRES EXPOSED, AND HAS BEEN ADDED.
> ELECTRICAL TO GARAGE HAS BEEN ADDED.
>ELECTRICAL TO FAMILY ROOM HAS BEEN ADDED.
INTERIOR ELECTRICAL:
>CANNED LIGHT IN ENTRY HALL HAS BEEN ADDED AND NOT PROPERLY MOUNTED TO CEILING.
>ENTIRE BUILDING,ALL RECEPS SHOW OPEN GROUND. TWO WIRE SYSTEM, THREE PRONG RECEPTICLES.
>BATH FAN NEEDS ADJUSTING.
>BATH RECEP NOT WORKING, FAN AND LIGHT WIRED TOGETHER.
>DOOR BELL WIRES EXPOSED IN HALL CLOSET.
>CANNED LIGHTS INKITCHEN HAVE BEEN ADDED.
>OUTLET UNDER KITCHEN SINK NOT PROPERLY MOUNTED.
INTERIOR FEATURES:
>FRONT DOOR DEADBOLT DOES NOT LOCK.
>FAMILY ROOM ADDED, WORK W/O PERMITS.
>GARAGE HAS BEEN ADDED, WORK W/O PERMITS,NO DOOR TO STRUCTURE AND THERE IS A WINDOW IN THE FIRE WALL.
>ENTRY HAS BEEN ADDED,W/O PERMITS.
>FAMILY ROOM DOOR LACKS WEATHER STRIP (PROTECTION)
>FAMILY ROOM WINDOWS NOT PROPERLY INSTALLED WINDOWS NOT ALWAYS LOCKING.
FIRE SAFETY: SMOKE DETECTORS IN ENTRY,LIVINGROOM AND HALL DID NOT HAVE WORKING SMOKE DETECTORS( WERE IN PLACE , BUT NOT WORKING)
INTERIOR PLUMBING:
>TOILET IN HALL BATH NOT WORKING.
>MASTER BATH TOILET LACKS TANK TOP.
>MAGNETIC LATCH ON SHOWER DOOR MISSING
>SHOWER FLOOR IN MASTER BATH SHOWER NEEDS TO BE CLEANED AND SEALED
>3/8" COPPER LINE IN FURNACE/ HOTWATER HEATER ROOM LEAKS AT SHUT OFF VALVE.
>WATER LINE TO COOLER LEAKS.
EXTERIOR FEATURES:
>PORCH APPEARS TO HAVE BEEN ADDED.
PORCH LACKS POST BASE.
PORCH POSTS LACK POST CAPS BOTH SIDES.
EAST BEAM SOUTH SIDE IS ROTTED.
RAFTERS CANNOT PROPERLY SUPPORT LOAD IMPOSED UPON
IT.
ADDED DOOR WAY TO PORCH, NORTH END, IMPROPERLY
SUPPORTS BEAM.
BEAM SPLICE NOT PROPERLY SUPPORTED
TRASH AND DEBRIS:
>REFUSE ACCUMULATED THROUGHOUT THE PROPERTY
>TRASH AND DEBRIS AND DEAD VEGETATION HAS ACCUMULATED THROUGHOUT THE PROPERTY.
>ABANDONED VEHICLE MUST BE REMOVED.
PICTURES WERE TAKEN!! NOV TO FOLLOW.