Case: T05DV00316

Parcel: 127050840


Addresses:

4749 E 1ST ST

Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Date Description Inspector Results Comments
05/10/2005 INSP - FOLLOW UP CODE ENFORCE Approved 05/10/05 VISITED SITE TOOK PICTURES, MET WITH OWNER OF DUPLEX MIKE LYLES.WENT OVER HOW INSPECTION WORKS. ASKED IF TENANT OF 4751 WAS AT HOME, HE SAID NO. MENTIONED THAT HIS WIFES PARENTS LIVED IN THE OTHER UNIT 4749 OF DUPLEX. ASKED IF HE WANTED ME TO INSPECT MAIN HOUSE, WHERE OWNER LIVED, HE SAID NO. TOLD HIM THAT I COULD SEE VIOLATIONS ON THE EXTERIOR OF UNITS,AND WOULD HAVE TO INSPECT VIOLATIONS ON THE EXTERIOR OF DUPLEX. MY FINDINGS ARE AS FOLLOWS:
ELECTRICAL:
>MAIN SERVICE PANEL MISSING DEAD PLATE AND KNOCK-OUTS
>UNIT 4751 SUB PANEL IS DOUBLE LUGGED.
>UNIT 4749 SUB PANEL HAS AN ILLEGAL SPLICE.
>ADDED ELECTRICAL FROM INTERIOR OF BOTH UNITS RUNNING TO THE COOLER OF EACH UNIT OVER THE ROOF.
PLUMBING: ( 4751)
>SEWER CLEAN OUT LACKS PLUG TO THE CAP
>VENT TO HOTWATER HEATER DOES NOT EXTEND 3' ABOVE ROOF LINE.
>COPPER TUBING FOR COOLER LINE NEEDS TO BE PROPERLY SUPPORTED TO WALL ( EVERY 4')
EXTERIOR FEATURES:
>4749 &4751, FACIA AND EVES ARE ROTTED, EVES HAVE HOLES AND ARE MISSING PLYWOOD IN AREAS.
> BACK PORCHES, BOTH UNITS, HAVE BEEN ADDED, POSSIBLE WORK W/O PERMITS.
>FRONT PORCHES, BOTH UNITS, LACK PROPER CONNECTING HARWARE IE. POST CAPS, H25 CLIPS, POST BASES.
>UNIT 4751 HAS A BROKEN WINDOW PANE AT FRONT WINDOW.
>UNIT 4749 MISSING WINDOW PANE AT FRONT WINDOW.
>UNIT 4749 SOUTHWEST WINDOW HAS BEEN BOARDED/EGRESS.
>ROOF AT REAR OF STRUCTURE NEEDS FLASHING WHERE HOUSE ROOF MEETS PORCH ROOF.
TRASH AND DEBRIS:
>REFRIGERATOR IN BACK YARD NEEDS TO BE REMOVED AS IT POSES A SAFETY HAZARD TO THE NEIGHBORING CHILDREN.