Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T05DV00232
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/29/2005 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 3/23/05, EMERGENCY CALL OUT PER CECI, T.P.D., VISITED SITE, TOOK PICTURES, MET WITH OFFICER JIMENEZ, WENT OVER ISSUES. UPON ARRIVAL COULD SEE 2 SEPERATE STRUCTURES ON SITE, YARDS FULL OF TRASH AND DEBRIS, EXCESSIVE BIKES AND BIKE PARTS. BOTH STRUCTURES LOOK DISTRESSED, STARTED WITH MAIN STRUCTURE, FRONT (NORTH SIDE) SET OF STAIRS ADDED TO ACCESS ROOF TOP, BEING USED AS A DECK, STAIRS WEAK AND WOBBLY, TREADS DETERIORATED, SPLITTING, FRONT WINDOWS BROKEN OUT 10 OF THEM, BEING COVERED BY WHITE PLEXI GLASS, NORTH SIDE HAS HAD ADDITIONS ADDED, 2 SEPERATE ROOMS, EAST SIDE OF MAIN STRUCTURE, NEW ELECTRIC SERVICE ADDED, DOUBLE LUGGED ON 30 AMP BREAKER, HAZARDOULY USING SEVERAL EXTENSION CORDS BEING USED TO SUPPLY POWER TO EXTERIOR LIGHTS, SPLICED AND TAPED TOGETHER, UPON ENTERING DWELLING LACKS SMOKE DETECTOR, APPEARS THE ONLY SOURCE OF HEAT IS A FIRE PLACE, TO SOUTH END TRASH AND DEBRIS SCATTERED ABOUT, NORTH END ADDITION IS BEING USED AS BEDROOM, BED FULL OF DEBRIS, PATHWAYS CLUTTERED, ONE WINDOW OPENS FOR EGRESS, INDOOR BLOWER MOTOR HAS BEEN INSTALLED FOR AIR MOVEMENT, HAZARDOUSLY USING EXTENSION CORD TO SUPPLY POWER TO MOTOR, SEVERAL EXTENSION CORDS BEING USED. KITCHEN HOT WATER CONTINOUSLY LEAKS AT KITCHEN SINK, HOT WATER HAS BEEN REPLACED, (ELECTRIC) MISSING COVER PLATE LEAVING OPEN AND EXPOSED WIRING, WATER LINES HAS BEEN REPLACED, BATH ROOM MISSING BATH SINK, SEWER LINE CAPPED. SHOWER AREA TILES BROKEN, NOT PROPERLY SEALED, SHOWER WATER HANDLE MISSING USING VISE GRIPS TO TURN ON AND OFF, WASHER AND DRYER ADDED, CAN NOT GET IN TO REAR TO SEE HOW DRAIN LINE CONNECTED, 2ND ROOM ADDED TO NORTH SIDE APPOX. 7' 14' FULL OF DEBRIS HAS COUCH FOR SITTING OR SLEEPING, MORE EXTENSION CORDS HAZARDOUSLY BEING USED TO SUPPLY POWER TO ROOM, ORIGINAL WINDOW REMOVED COVERED WITH BLANKET, GOES BETWEEN ORIGINAL STRUCTURE AND ADDITION, EXTERIOR ON WEST SIDE HAS PORCH ADDED, WILL NOT PASS CODE INSP. TO LOW APPOX. 6' IN HIEGHT, THIS AREA HAS MOST ACCUMULATION OF BIKES AND BIKE PARTS ALOT, MORE EXTENSION CORDS HAZARDOUSLY BEING USED TO SUPPLY POWER TO LIGHTS AND TO 2ND STRUCTURE, 2ND STRUCTURE IS GARAGE TYPE, HAS BEEN SEPERATED ON INTERIOR INTO SEPERATE ROOMS, MORE BIKES AND PARTS, MORE EXTENSION CORDS HAZARDOUSLY BEING USED, HAS ELECTRICAL SERVICE BOX ON EAST WALL MISSING COVER PLATE, OPEN AND EXPOSED WIRING, SEVERAL EXTENSION CORDS HAZARDOUSLY BEING RAN ALONG CEILING, TO POWER STRIP WITH SEVER CONNECTED, CAN NOT NAVAGATE THROUGH 2ND STRUCTURE VERY WELL, CAN NOT GET TO ELECTRIC SERVICE DUE TO BIKES AND PARTS. CALLED AND TALKED WITH INSP. 2 RICK, WENT OVER ISSUES ON PROPERTY, NOT BAD ENOUGH TO CLOSE DOWN, CLOSE TO BOARDER LINED, INSP. 2 CONCURRED TO GIVE NOTICE AND ORDER FOR REMOVAL OF ALL EXTENSION CORDS, 5 DAYS, AND TO REORGANIZE INTERIOR FOR BETTER ACCESS TO ALL EGRESSES. 25 DAYS. OCCUPANT LOREN BEASLEY RETURNED TO PROPERTY AT THIS TIME WENT OVER ISSUES OF HAZARDOUSLY USING EXTENSION CORDS AND MUST BE REMOVED LOREN CONCURRED, ALSO WENT OVER ISSUES OF REORGANIZING DEBRIS ON INTERIOR FOR BETTER ACCESS TO INTERIOR EGRESSES, AGAIN LOREN CONCURRED, LOREN STAYED ON SITE UNTIL I FINISHED WITH NOTICE AND ORDER LOREN SIGNED N/O, LOREN AGREED TO CORRECT ISSUES. LEFT SITE. F/U 5 DAYS. FOR EXTENSION CORD ISSUE. |
|
| 03/29/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | MET WITH RYAN ON SITE. YESTERDAY RYAN MENTIONED THAT HE WOULD MEET WITH US HERE TODAY AND HAVE EXTENSION CORDS REMOVED. FOUND EXTENSION CORDS HAD BEEN REMOVED FROM AREA'S WHERE THEY WERE INITIALL FOUND. THERE WERE NOT CORDS RUNNING OUT OF THE WINDOWS, NO CORDS LYING INSIDE THE STRUCTURE ON THE FLOOR. THERE WERE NO EXTENSION CORDS BEING RUN TO THE SHIP AREA. THE WIRE ON BACK PROCH HAD BEEN MAILED UP TO RAFTERS (2) NAILS, AND COVER WAS PUT ON. ELECTRICAL COVERS WERE MISSING INSIDE THE HOUSE, BROKEN OUTLET SIGHTED. IN THE SHOP THE MAIN OUTLET WAS COVERED WITH WOOD AS ASKED BY C-13 WIRES WERE ROLLED UP AND STAPLED TO RAFTERS. OUTSIDE PORCH AREA HAD BEEN SIGNIFICANTLY CLEANED UP, BICYCLE PARS WERE PUT IN SOME KIND OF ORDER BY PARTS/FRAMES AND WHEELS TOGETHER. RYAN ASKED FOR PAPER WORK TO START MAKING REPAIRS, TOLD HIM NOV WOULD BE ISSUED BY END OF WEEK. PICTURES WERE TAKEN. | |
| 03/28/2005 | INSP - INITIAL CODE ENFORCMENT | Approved | REVISITED SITE TO CHECK ELECTRICAL CORDS AND FIND IF THEY HAD BEEN REMOVED. FOUND THREE GENTLEMEN IN THE PROCESS OF CLEANING UP SOME ELECTRICAL CORDS HAS BEEN UNPLUGGED BUT NOT REMOVED. TOLD THEM CORDS HAD TO BE REMOVED. THEY SAID THEY WOULD. ASKED RYAN TO PLEASE MEET US THERE FOR REINSPECTION OF CORDS. |